2-2-4 ALUMINUM SER CABLE

2-2-4 ALUMINUM SER CABLE
Roll over image to Zoom
2-2-4 ALUMINUM SER CABLE
Roll over image to Zoom
2-2-4 ALUMINUM SER CABLE
SKU: NNC1689X
aluminum-ser-service-entrance-type-r-cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$1.86 /FT
Sale price
$1.86 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 5 reviews
100%
(5)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
Jeffrey Kenney

2-2-4 ALUMINUM SER CABLE

T
Tom Smith
Great service

Got my wire as promised in a quick manner. Very satisfied. Will use them in the future.

J
John Elliott

It arrived earlier than I thought it was going to and it was cheaper than anybody else thank you so much

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

2-2-4 ALUMINUM SER CABLE

Allowable Ampacity for 2-2-4 ALUMINUM SER CABLE at 60°C: 75 Amps

Allowable Ampacity for 2-2-4 ALUMINUM SER CABLE at 75°C: 90 Amps

Allowable Ampacity for 2-2-4 ALUMINUM SER CABLE at 90°C: 100 Amps

Applications:

Aluminum service entrance cable is mainly used in branch circuits and panel feeders. The voltage rating for this electrical cable is 600 volts. Aluminum service entrance cables are designed for use in adverse weather conditions, with operating temperatures being 90°C in both wet and dry locations.

However, type R cables can operate at 60°C when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. In addition, SER cables can operate at 70°C when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge.

This particular 2-2-4 size, with an ampacity of 100 Amps, is commonly used for:

  • Main panel feeds in residential homes.
  • Subpanel feeds in homes, garages, and workshops.
  • Power distribution from meter bases to panelboards.
  • Supplying power to mid-range electrical appliances, such as HVAC systems and electric water heaters.

Also Known As:

2-2-4 type r cable, 2-2-4 service entrance cable, 2-2-4 ser cable, 2-2-4 aluminum ser cable, 2-2-4 aluminum service entrance cable, 2-2-4 electrical entrance cable.

Standards:

  • Ampacities based on National Electric Code, 2005 edition, section 310-15 

  • 60°C, when terminated to equipment for circuits, rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 

  • 70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge 

  • 90°C wet or dry locations 

  • For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load 

  • UL 44


Construction

Conductors:

Aluminum type R cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current. 

Insulation:

Aluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section. 

Assembly:

Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tape.

Jacket:

The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.

Specifications:

  • Insulated Cond(s) Size AWG: 2

  • Bare Conductor Size AWG: 4

  • Nominal O.D. Inches: 0.748

  • Approx. Weight lb/1000FT: 254 lbs

  • Ampacity at 90°C: 100 Amps

  • Ampacity in dwelling: 100 Amps

Compatible with Manufacturer

Houston Wire & Cable : HW022A00224

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What does 2-2-4 AL SER mean?

Two 2 AWG aluminum hots and one 4 AWG aluminum neutral.

What is SER cable?

SER is a NEMA and UL type designation for Service Entrance cable, Style R. "SE" identifies it as service entrance cable, and "R" designates the construction style: the individually insulated conductors are cabled together and covered by a moisture and flame-resistant jacket over a reinforcement tape or braid layer. This distinguishes it from Style U (SEU), where a bare concentric neutral is wound around the insulated conductors under the jacket. SER is rated 600V and governed by NEC Article 338.

Does 2-2-4 AL SER include a ground wire?

No. For subpanel and feeder applications requiring an equipment grounding conductor, use 2-2-2-4 AL SER.

What is the main difference between SER and SEU cable?

SER (Style R) has separate insulated hot and neutral conductors plus an equipment grounding conductor. This four-conductor construction makes SER suitable for runs from a main service panel to a subpanel, such as a panel in a detached garage, workshop, or another part of a building.

SEU (Style U) has insulated hot conductors surrounded by a bare concentric neutral and does not include a separate equipment grounding conductor. It is therefore mainly used on the service side of the electrical system, for example, between the meter and the main service panel, where neutral and ground are bonded at the service equipment.

What are the permitted uses for 2-2-4 AL SER?

2-2-4 AL SER is used for service entrance runs and two-wire feeder applications up to 100A. Typical uses include the drop from the meter to a 100A main panel, or a feeder to an outbuilding where an equipment grounding conductor is not required at the source side. For four-wire subpanel and detached structure feeders, use 2-2-2-4 AL SER.

Can 2-2-4 AL SER be used for a subpanel?

No. Use 2-2-2-4 AL SER instead when the application requires an equipment grounding conductor.

Can AL SER cable be used for direct burial?

No. Standard AL SER is not rated for direct burial. For underground runs, use USE or USE-2 cable, or install AL SER inside a listed underground raceway.

Is AL SER cable rated for outdoor use?

Yes, most modern AL SER is listed for outdoor use when properly supported and protected from physical damage per NEC 338.10 and 230.51.

How far can I run 2-2-4 AL SER before voltage drop becomes a problem?

At 100A on 240V, roughly 113 feet within 3% drop.

How do I identify different types of aluminum AL SER cables?

Aluminum AL SER is identified by the conductor size sequence printed on the jacket, such as 2-2-4 AL SER or 4/0-4/0-4/0-2/0 AL SER. The sequence lists hot conductors first, then the neutral, and where present the equipment grounding conductor last. Fraction sizes (1/0, 2/0, 3/0, 4/0) indicate larger AWG, and numbers followed by "kcmil" indicate conductors sized in thousand circular mils.

Reviews

Customer Reviews

Based on 5 reviews
100%
(5)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
Jeffrey Kenney

2-2-4 ALUMINUM SER CABLE

T
Tom Smith
Great service

Got my wire as promised in a quick manner. Very satisfied. Will use them in the future.

J
John Elliott

It arrived earlier than I thought it was going to and it was cheaper than anybody else thank you so much

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460