700 MCM XHHW-2 Aluminum Building Wire 600V | Nassau Cable
nassaunationalcable.com/products/700-mcm-xhhw-2-aluminum-cable-600v
Items in Cart ()
View cart

700 MCM XHHW-2 Aluminum Building Wire 600V

700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
700 MCM XHHW-2 Aluminum Building Wire 600V
SKU: NNC1859X
xhhw-2-aluminum-building-wire-600v

Availability: In stock

Price:
Regular price
$4.94 /FT
Sale price
$4.94 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

700 MCM XHHW-2 Aluminum Building Wire 600V

Allowable Ampacity for 700 MCM XHHW-2 Aluminum Cable 600V at 75°C: 375 Amps

Allowable Ampacity for 700 MCM XHHW-2 Aluminum Cable 600V at 90°C: 425 Amps

700 MCM aluminum XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, made to be installed in conduit or other raceways. It's rated for wet and dry locations at up to 90°C and 600V.

Applications:

700 MCM aluminum XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 375A at 75°C and 425A at 90°C. Typical uses:

  • 350A feeders at full rating

  • 700A services run as two parallel sets

  • 1000A services run as three parallel sets

  • Transformer secondary conductors in commercial and industrial buildings

Also Known As:

700 xhhw-2 cable, 700 hxxw-2 cable, 700 rw90 cable, 700 rw90 wire, 700 type se cable style u type xhhw-2, 700 xhhw-2, 700 southwire xhhw-2, 700 xhhw-2 insulation.

700 MCM XHHW-2 Aluminum Data Center Applications

In data centers, 700 MCM aluminum XHHW-2 is used for long service and generator feeders, where its lower cost and weight add up across paralleled sets. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated. Terminations must be rated for aluminum.

  • Three parallel sets for 1000A service feeders

  • Two parallel sets for 700A distribution feeders

  • Long feeders from outdoor generators to paralleling switchgear

Standards:

  • XHHW-2 meet or exceed the following standards: 

  • UL standard 44 

  • Requirements of the National Electrical Code 

  • ASTM standards B 800, B 801 

  • Federal Specification J–C-30B 

  • Sunlight resistant

Construction

Conductors:

Compact bare AA-8000 series aluminum alloy, Class B stranded per ASTM

Insulation:

XHHW-2 has abrasion, heat, and moisture resistant cross-linked polyethylene insulation. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions.

Specifications:

  • Size AWG: 700 MCM

  • Stranding: 58

  • Conductor Diameter Inches: 0.877

  • Insulation Thickness Inches: 0.080

  • O.D. Inches:  1.037

  • New Weight lb/1000FT: 765 lbs

  • Ampacity at 75°C: 375 Amps

  • Ampacity at 90°C: 425 Amps

Compatible with Manufacturer

Houston item : Black : HW002A70001
Black : 700-01XHHWBLACKAL
Priority Wire & Cable : Black : 700-01XHHW-2-ALUM
Southwire : Black : 27840899
Orange :
57634299
Yellow :
57634399
Brown :
57634199
Gray : 57634499



*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 700 MCM aluminum XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 700 MCM aluminum XHHW-2 has a compact AA-8000 series alloy conductor, is installed in conduit or other NEC-recognized raceways at up to 600V, and is rated 375A at 75°C. It's used for 350A feeders, 700A and 1000A services in parallel sets, and transformer secondaries.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Is 700 MCM aluminum XHHW-2 used in data centers?

Yes. 700 MCM aluminum XHHW-2 runs in three parallel sets for 1000A service feeders and on long generator feeders to paralleling switchgear. Terminations must be rated for aluminum.

Reviews