600 MCM XHHW-2 Aluminum Building Wire 600V

600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
600 MCM XHHW-2 Aluminum Building Wire 600V
SKU: NNC1850X
xhhw-2-aluminum-building-wire-600v

Availability: In stock

Price:
Regular price
$4.30 /FT
Sale price
$4.30 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

600 MCM XHHW-2 Aluminum Building Wire 600V

Allowable Ampacity for 600 MCM XHHW-2 Aluminum Cable 600V at 75°C: 340 Amps

Allowable Ampacity for 600 MCM XHHW-2 Aluminum Cable 600V at 90°C: 385 Amps

600 MCM aluminum XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, made to be installed in conduit or other raceways. It's rated for wet and dry locations at up to 90°C and 600V.

Applications:

Type XHHW-2/RW90 wires are primarily used in conduit or recognized raceways for services, feeders, and branch circuit wiring as specified in the National Electrical Code or the Canadian Electrical Code. XHHW-2/RW90 conductors may be used in wet or dry locations at temperatures not to exceed 90oC. Voltage rating for XHHW-2 conductors is 600 or 1000 volts, or 600 volts for RW90. CT - Rated Cable tray rated for 1/0 AWG and larger available upon request.

 600 MCM XHHW-2 Aluminum Cable is used for:

  • 400A home services in a single run under NEC 310.12
  • 600A services run as two parallel sets
  • 1000A services run as three parallel sets
  • Inverter output and AC collection feeders on commercial solar projects
  • Service entrance
  • Major feeder circuits
  • Large-scale industrial equipment
  • Conduit systems
  • Busbars and power distribution systems
  • Massive renewable energy installations
  • Backup generators

Also Known As:

600 mcm aluminum wire, 600 xhhw-2 cable, 600 hxxw-2 cable, 600 rw90 cable, 600 rw90 wire, 600 type se cable style u type xhhw-2, 600 xhhw-2, 600 southwire xhhw-2, 600 xhhw-2 insulation, 600 kcmil aluminum wire, 600 aluminum wire.

600 MCM XHHW-2 Aluminum Data Center Applications

In data centers, 600 MCM aluminum XHHW-2 is used for long service and generator feeders, where its lower cost and weight add up across paralleled sets. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated. Terminations must be rated for aluminum.

  • Three parallel sets for 1000A service and distribution feeders

  • Two parallel sets for 400 kVA UPS input (481A full load, 601A at 125%)

  • Long feeders from outdoor generators to transfer switches

Standards:

  • XHHW-2 meet or exceed the following standards: 
  • UL standard 44 
  • Requirements of the National Electrical Code 
  • ASTM standards B 800, B 801 
  • Federal Specification J–C-30B 
  • Sunlight resistant

Construction

Conductors:

Compact bare AA-8000 series aluminum alloy, Class B stranded per ASTM

Insulation:

XHHW-2 has abrasion, heat, and moisture resistant cross-linked polyethylene insulation. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions.

Specifications:

  • Size AWG: 600 MCM
  • Stranding: 58
  • Conductor Diameter Inches: 0.813
  • Insulation Thickness Inches: 0.080
  • O.D. Inches:  0.973
  • New Weight lb/1000FT: 664 lbs
  • Ampacity at 75°C: 340 Amps
  • Ampacity at 90°C: 385 Amps

Compatible with Manufacturer

Houston item : Black : HW002A60001
Black : 600-01XHHWBLACKAL
Priority Wire & Cable : Black : 600-01XHHW-2-ALUM
Omni Cable item : Black : M8600ST-01
Blue : M8600ST-05
Green : M8600ST-04
Orange :
M8600ST-07
Red :
M8600ST-03
White :
M8600ST-02
Yellow :
M8600ST-08
Brown :
M8600ST-010
Gray :
M8600ST-06
Southwire : Black : 27839001
Blue : 57635199
Green : 56737599
Orange :
57634699
Red :
57635099
White :
57635299
Yellow :
57634799
Brown :
57634599
Gray : 57634999

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 600 MCM aluminum XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 600 MCM aluminum XHHW-2 has a compact AA-8000 series alloy conductor, is installed in conduit or other NEC-recognized raceways at up to 600V, and is rated 340A at 75°C. It's used for 400A home services in a single run, 600A and 1000A services in parallel sets, and solar inverter output feeders.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Is 600 MCM aluminum XHHW-2 used in data centers?

Yes. 600 MCM aluminum XHHW-2 runs in three parallel sets for 1000A service feeders and on long runs from outdoor generators to transfer switches. Terminations must be rated for aluminum.