750 MCM XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/products/750-mcm-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

750 MCM XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
750 MCM XHHW-2 Stranded Copper Building Wire
SKU: NNC2516X2
xhhw-2-copper-building-wire-conductor

Availability: In stock

Price:
Regular price
$40.09 /FT
Sale price
$40.09 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

750 MCM XHHW-2 Stranded Copper Building Wire

Allowable Ampacity (Per NEC Table 310.16):

  • 60°C: 400 Amps
  • 75°C: 475 Amps
  • 90°C (XHHW-2 Rating): 535 Amps

Description:

750 MCM XHHW-2 Copper Building Wire is a stranded conductor with cross-linked polyethylene (XLPE) insulation, designed for use in conduit, raceways, and feeders where high ampacity and durability are required. Rated for 600V, it operates in wet, dry, and corrosive environments, with a maximum temperature rating of 90°C.

Also Known As:

750 XHHW-2 Copper Building Wire, 750 XHHW Cable, 750 XHHW Service Wire, 750 XHHW Copper Wire, 750 MCM XHHW Wire, 750 MCM Copper XHHW-2 Cable, 750 MCM Electrical Wire, 750 MCM Stranded Copper XHHW-2.

Applications

750 MCM copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 475A at 75°C and 535A at 90°C. Typical uses:

  • 450A feeders at full rating

  • 800A services run as two parallel sets

  • 1200A services run as three parallel sets

  • UPS and switchboard feeders in data centers

750 MCM XHHW-2 Copper Data Center Applications

In data centers, 750 MCM copper XHHW-2 is used for feeders between switchgear, UPS systems, PDUs, and panels. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.

  • Single-run feeders for 300 kVA PDUs and transformers (361A full load, 451A at 125%)

  • Two parallel sets for 600 kVA UPS systems (722A full load, 902A at 125%)

  • Four parallel sets for 1600A main switchboards

Construction:

Conductor:

  • Material: Annealed bare copper (concentrically stranded)
  • Properties: High conductivity, moisture resistance, and excellent durability

Insulation:

  • Material: Cross-linked polyethylene (XLPE)
  • Properties: Flame-retardant, resistant to chemicals, moisture, and abrasion

Standards & Compliance:

  • UL Standard 44 – Thermoset-Insulated Wires and Cables
  • ASTM B3 & B8 – Soft and Concentric-Lay-Stranded Copper Conductors
  • Federal Specification A-A-59544
  • RoHS/REACH Compliant
  • NEC Article 310.16 – Ampacity Ratings
  • ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less

Specifications:

  • Size: 750 MCM
    Number of Strands: 61
    Diameter Over Conductor (Inches): 0.865
    Insulation Thickness (mils): 80
    Weight per 1,000 ft: 2449 lbs
    Jacket: XLPE

Compatible with Manufacturer

Advanced Digital : 

20600CT

Omni Cable :

Black : M7600ST-01
White : M7600ST-02
Red : M7600ST-03
Green : M7600ST-04
Blue : M7600ST-05
Gray : M7600ST-06
Orange : M7600ST-07
Yellow : M7600ST-08
Purple : M7600ST-09
Brown : M7600ST-10
Pink : M7600ST-11
Tan : M7600ST-12

Southwire :

Black : 11310099
White : 55392699
Red : 55392701
Blue : 55392899
Green : 55392999

Yellow : 55393299
Orange : 55393199
Brown : 55393099
Gray : 55393499

HWC : 

HW00275001

Service Wire Co : 

XH600BK


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 750 MCM copper XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 750 MCM copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 475A at 75°C. It's used for 450A feeders, 800A and 1200A services in parallel sets, and data center switchboard feeders.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Is 750 MCM copper XHHW-2 used in data centers?

Yes. A single run of 750 MCM copper XHHW-2 feeds a 300 kVA PDU or transformer (451A at 125%), and four parallel sets feed 1600A main switchboards.