750 MCM XHHW-2 Stranded Copper Building Wire
Allowable Ampacity (Per NEC Table 310.16):
- 60°C: 400 Amps
- 75°C: 475 Amps
- 90°C (XHHW-2 Rating): 535 Amps
Description:
750 MCM XHHW-2 Copper Building Wire is a stranded conductor with cross-linked polyethylene (XLPE) insulation, designed for use in conduit, raceways, and feeders where high ampacity and durability are required. Rated for 600V, it operates in wet, dry, and corrosive environments, with a maximum temperature rating of 90°C.
Also Known As:
750 XHHW-2 Copper Building Wire, 750 XHHW Cable, 750 XHHW Service Wire, 750 XHHW Copper Wire, 750 MCM XHHW Wire, 750 MCM Copper XHHW-2 Cable, 750 MCM Electrical Wire, 750 MCM Stranded Copper XHHW-2.
Applications
750 MCM copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 475A at 75°C and 535A at 90°C. Typical uses:
-
450A feeders at full rating
-
800A services run as two parallel sets
-
1200A services run as three parallel sets
-
UPS and switchboard feeders in data centers
750 MCM XHHW-2 Copper Data Center Applications
In data centers, 750 MCM copper XHHW-2 is used for feeders between switchgear, UPS systems, PDUs, and panels. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.
-
Single-run feeders for 300 kVA PDUs and transformers (361A full load, 451A at 125%)
-
Two parallel sets for 600 kVA UPS systems (722A full load, 902A at 125%)
-
Four parallel sets for 1600A main switchboards
Construction:
Conductor:
- Material: Annealed bare copper (concentrically stranded)
- Properties: High conductivity, moisture resistance, and excellent durability
Insulation:
- Material: Cross-linked polyethylene (XLPE)
- Properties: Flame-retardant, resistant to chemicals, moisture, and abrasion
Standards & Compliance:
- UL Standard 44 – Thermoset-Insulated Wires and Cables
- ASTM B3 & B8 – Soft and Concentric-Lay-Stranded Copper Conductors
- Federal Specification A-A-59544
- RoHS/REACH Compliant
- NEC Article 310.16 – Ampacity Ratings
- ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
Specifications:
-
Size: 750 MCM
Number of Strands: 61
Diameter Over Conductor (Inches): 0.865
Insulation Thickness (mils): 80
Weight per 1,000 ft: 2449 lbs
Jacket: XLPE
|
Compatible with Manufacturer |
|
|
Advanced Digital : |
20600CT |
|
Omni Cable : |
Black : M7600ST-01 |
|
Southwire : |
Black : 11310099 |
|
HWC : |
HW00275001 |
|
Service Wire Co : |
XH600BK |
FAQ's
What is 750 MCM copper XHHW-2 used for?
What are the main differences between XHHW and XHHW-2 wires?
What is the difference between THHN and XHHW-2 wire?
Can XHHW-2 wire be buried underground?
Does XHHW-2 wire have to be run in conduit?
Is XHHW-2 wire sunlight resistant?
Can XHHW-2 wire be used in cold weather?
Is 750 MCM copper XHHW-2 used in data centers?
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
Garrie AI: Your Cable Guide