10 AWG XHHW-2 Stranded Copper Building Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
10 AWG XHHW-2 Stranded Copper Building Wire
Description:
XHHW-2 copper conductors are primarily used in conduit, recognized raceways, and branch circuit wiring, as outlined in the National Electrical Code (NEC). These conductors are suitable for wet and dry locations, with a maximum operating temperature of 90°C. They have a voltage rating of 600 volts. Certain XHHW-2 conductors may be used in health care facilities under NEC Section 517.160 if they meet the dielectric constant requirement of less than 3.5.
Also Known As:
10 XHHW-2 Copper Building Wire, 10 XHHW Cable, 10 XHHW Service Wire, 10 XHHW Copper Wire, 10 CU Building Wire, 10 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11294604, Southwire Wire, 10 AWG XHHW Building Wire, 10 Gauge Stranded Copper XHHW-2 Wire, 10 Stranded Copper XHHW-2 Wire.
Common Uses of 10 AWG Copper XHHW-2 Wire
- 30A branch circuits in residential and commercial buildings
- 35A branch circuits where the 75°C ampacity is permitted, such as conductors installed in conduit.
- 40A circuits when used per NEC adjustments in specific applications, such as feeder circuits in low-load conditions
- Feeder wiring for appliances, lighting, and power distribution
- HVAC and refrigeration unit wiring
- Motor leads for small to medium-sized motors in wet or dry environments
- Power distribution in conduit and raceways for 600V-rated applications
- 30A circuits for water heaters, dryers, and small A/C condensers
- PV source and output circuits run in conduit to the inverter
- 30A feeds to small subpanels and equipment disconnects
- Long 20A runs upsized to 10 AWG to limit voltage drop
10 AWG Stranded XHHW-2 Copper Data Center Applications
In data centers, 10 AWG stranded copper XHHW-2 is pulled in conduit and flexible metal conduit for rack branch circuits. NEC 210.19 sizes these circuits at 125% of the continuous load, and the 90°C rating gives headroom when many circuits share one raceway.
-
30A, 208V single-phase rack circuits with L6-30 receptacles
-
30A, 208V three-phase rack circuits with L21-30 receptacles, about 8.6 kW per circuit at 80% loading
-
Whips from remote power panels to racks, in flexible metal conduit under raised floors (NEC 645.5(E))
-
With 4 to 6 current-carrying conductors in one conduit, the 90°C rating (40A x 80% = 32A) still covers a 30A circuit
Construction:
Conductor:
- Material: Annealed bare copper, concentrically stranded
- Properties: High electrical conductivity, resistant to moisture, compression, pressure, and heat
Insulation:
- Material: Cross-linked polyethylene (XLPE)
- Properties: Flame-retardant, resistant to abrasion, chemicals, corrosion, and moisture
- Color: Black (standard)
Standards & Compliance:
- ASTM B3 – Soft or Annealed Copper Wire
- ASTM B8 – Concentric-Lay-Stranded Copper Conductors
- UL 44 – Thermoset-Insulated Wires and Cables
- ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
- Federal Specification A-A-59544
- NMX-J-451-ANCE – Thermoset insulated wires and cables
- NOM-063-SCFI – Electrical Conductors Safety Requirements
- Buy American & Buy America Act (BAA) Compliant (49 U.S.C. § 5323(j) and 49 C.F.R. part 661)
Specifications:
-
Size AWG: 10
Weight per 1,000 ft: 39 lbs
Outside Diameter: 0.173 inches
Number of Strands: 7
Jacket: XLPE
Min Bending Radius: 0.7 inches
Max Pull Tension: 83 lbs
Insulation Thickness: 30 mils
Allowable Ampacity At 60°C: 30 Amp
Allowable Ampacity At 75°C: 35 Amp
Allowable Ampacity At 90°C: 40 Amp
Southwire Part (SimPull): 11294604
|
Manufacturer Equivalents |
|
|
Advanced Digital : |
Black : 208 |
|
Aetna Digital : |
Black : 117-4400C |
|
Draka : |
Black : 6200110bk |
|
General Cable : |
Black : 798751 |
| Kalas : |
Black : t.b.d. White : t.b.d. Red : t.b.d. Green : t.b.d. |
|
Omni Cable : |
Black : M708ST-01 |
|
Southwire : |
Black : 11294604 |
FAQ's
What is 10 AWG stranded copper XHHW-2 used for?
What are the main differences between XHHW and XHHW-2 wires?
What is the difference between THHN and XHHW-2 wire?
Should I choose solid or stranded 10 AWG XHHW-2?
How many 10 AWG XHHW-2 wires fit in 3/4" conduit?
Can XHHW-2 wire be buried underground?
Does XHHW-2 wire have to be run in conduit?
Is XHHW-2 wire sunlight resistant?
Can XHHW-2 wire be used in cold weather?
Can XHHW-2 be used as PV wire?
Is 10 AWG stranded copper XHHW-2 used in data centers?
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460