4/0-4/0-2/0 ALUMINUM SEU CABLE

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
4/0-4/0-2/0 ALUMINUM SEU CABLE
Allowable Ampacity for 4/0-4/0-2/0 ALUMINUM SEU CABLE at 60°C: 150 Amps
Allowable Ampacity for 4/0-4/0-2/0 ALUMINUM SEU CABLE at 75°C: 180 Amps
Allowable Ampacity for 4/0-4/0-2/0 ALUMINUM SEU CABLE at 90°C: 205 Amps
Applications:
Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature of this electrical cable is not to exceed 90°C in wet locations. Voltage rating for this electrical cable is 600 volts.
This 4/0-4/0-2/0 size, with an ampacity of 200 Amps in dwelling applications, is commonly used for:
- Main service panel feeds in large residential homes.
- Meter-to-panel connections in single-family dwellings.
- 200 Amp service upgrades or replacements.
Also Known As:
4/0-4/0-2/0 aluminum seu cable, 4/0-4/0-2/0 seu service entrance cable, 4/0-4/0-2/0 seu cable, 4/0-4/0-2/0 seu wire, 4/0-4/0-2/0 600v wire, 4/0-4/0-2/0 600v cable, seu cable for 200 amp service
Standards:
-
Ampacities based on National Electric Code, 2005 edition, section 310-15
-
60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors
-
70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge
-
90°C wet or dry locations
-
For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service conductors that supply the total load
-
UL 44, 854
-
Federal Specification J-C - 30B
Construction
Conductors:
Aluminum SEU cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current.
The "4/0-4/0-2/0" designation means this SEU cable contains three conductors:
- Two phase conductors (hot wires) sized 4/0 AWG for carrying current.
- One neutral conductor, which also serves as the ground conductor, sized 2/0 AWG.
Insulation:
Aluminum SEU cable has a type XHHW-2 cross-linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section.
Jacket:
The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.
Specifications:
-
Insulated Cond(s) Size AWG: 4/0
-
Bare Conductor Size AWG: 2/0
-
Nominal O.D. Inches: 0.818
-
Approx. Weight lb/1000FT: 1003 lbs
-
Ampacity at 90°C: 205 Amps
-
Ampacity in dwelling: 200 Amps
Compatible with Manufacturer |
|
Priority Wire & Cable : | 4/0-02ALUMG-R-SEU |
Southwire : | 13097101 |
Houston : | HW021A40220 |
Omni Cable : | SEU4/02C-2/0 |