1000 MCM XHHW-2 Stranded Copper Building Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
1000 MCM XHHW-2 Stranded Copper Building Wire
Allowable Ampacity (Per NEC Table 310.16):
- 60°C: 455 Amps
- 75°C: 545 Amps
- 90°C (XHHW-2 Rating): 615 Amps
Description:
1000 MCM XHHW-2 Copper Building Wire is a stranded conductor with cross-linked polyethylene (XLPE) insulation, designed for use in conduit, raceways, and feeders where high ampacity and durability are required. Rated for 600V, it operates in wet, dry, and corrosive environments, with a maximum temperature rating of 90°C.
Also Known As:
1000 XHHW-2 Copper Building Wire, 1000 XHHW Cable, 1000 XHHW Service Wire, 1000 XHHW Copper Wire, 1000 MCM XHHW Wire, 1000 MCM Copper XHHW-2 Cable, 1000 MCM Electrical Wire, 1000 MCM Stranded Copper XHHW-2.
Applications:
- 500A feeders in a single run
- 1000A services run as two parallel sets
- 1600A services run as three parallel sets
- Transformer secondaries and switchgear in industrial plants
- Primary and secondary feeders in large commercial and industrial buildings
- Underground conduit installations where moisture resistance is required
- Main service conductors for high-load electrical panels
- Backup generator wiring for hospitals, data centers, and critical facilities
- Cable tray wiring in industrial settings requiring high ampacity
1000 MCM XHHW-2 Copper Data Center Applications
In data centers, 1000 MCM copper XHHW-2 is used for feeders between switchgear, UPS systems, PDUs, and panels. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.
-
Two parallel sets for 1000A feeders
-
Three parallel sets for 1000 kVA UPS systems (1203A full load, 1504A at 125%)
-
Four parallel sets for 2000A switchboards, with fewer conductors per phase than smaller sizes in tight electrical rooms
Construction:
Conductor:
- Material: Annealed bare copper (concentrically stranded)
- Properties: High conductivity, moisture resistance, and excellent durability
Insulation:
- Material: Cross-linked polyethylene (XLPE)
- Properties: Flame-retardant, resistant to chemicals, moisture, and abrasion
Standards & Compliance:
- UL Standard 44 – Thermoset-Insulated Wires and Cables
- ASTM B3 & B8 – Soft and Concentric-Lay-Stranded Copper Conductors
- Federal Specification A-A-59544
- RoHS/REACH Compliant
- NEC Article 310.16 – Ampacity Ratings
- ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
Specifications:
-
Size: 1000 MCM
Number of Strands: 61
Diameter Over Conductor (Inches): 1.117
Insulation Thickness (mils): 80
Weight per 1,000 ft: 3240 lbs
Insulation: XLPE
|
Compatible with Manufacturer |
|
|
Southwire : |
Black : 11313499 |
|
HWC : |
HW00210001 |
|
Service Wire Co : |
XH600BK |
FAQ's
What is 1000 MCM copper XHHW-2 used for?
What are the main differences between XHHW and XHHW-2 wires?
What is the difference between THHN and XHHW-2 wire?
Can XHHW-2 wire be buried underground?
Does XHHW-2 wire have to be run in conduit?
Is XHHW-2 wire sunlight resistant?
Can XHHW-2 wire be used in cold weather?
Is 1000 MCM copper XHHW-2 used in data centers?
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
Garrie AI: Your Cable Guide