8/3 W/GRND NM-B 600V Stranded Black
nassaunationalcable.com/products/8-3-w-grnd-nm-b-600v-stranded-black

Items in Cart ()

View cart

8/3 W/GRND NM-B 600V Stranded Black

8/3 W/GRND NM-B 600V Stranded Black
Roll over image to Zoom

8/3 W/GRND NM-B 600V Stranded Black

SKU: NNC2603X

Availability: In stock

Price:
Regular price
$5.00
Sale price
$2.59 /FT 48% off
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 35 reviews
100%
(35)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
Joao Reis

Great product. Fast delivery.

J
James
8/3 romex

Great insulation jacket, tightly wound inner wires, easy pull, easy termination.

S
Steven Jones
Excellent cable, low price

8/3 cable is excellent quality, cut exactly to the length requested, at a low price. Great deal.

T
Tim Spangler

Awesome people to deal with never a problem

T
Timothy Boudreaux
Great Deal

Great deal and helpful service

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

8/3 W/GRND NM-B 600V Stranded Black

Allowable Ampacity for 8-3 W/GRND NM-B(amp rating): 40 Amps

Also Known As:

8-3 NM-B Wire, 8-3 NM-B Cable, 8-3 Non-Metallic Sheathed Cable, 8-3 Non-Metallic Sheathed Wire, 8-3 W Grnd NM-B, 8-3 Type NB Copper Building Wire, 8-3 Type NB Copper Building Wire, 8/3 Electrical Wire, 8/3 Indoor Wire, 8/3 White Wire, 8/3 NM Cable, 8/3 NM Wire, 8/3 Residential Cable, 8/3 House Wire, 8/3 Home Wiring Cable, 8/3 Branch Circuit Wire, 8/3 Grounded Wire.

8/3 NM-B Applications:

Applications:

Type NM-B Copper Building Wire is commonly applied in residential building wiring and branch circuits for switches and outlets. wire is for dry indoor applications. 8/3 can also be used for various building purposes inside (the temperature should not exceed 90 °C). 8/3 NM-B electrical wire can be used in air voids in tile walls. The voltage rating of the 8 Gauge is 600 volts. The 8/3 electrical wire is easily installed because it is specifically designed for easier pulling. 


The range of NM-B applications includes:

  • Residential electric systems, including lights, switches, and outlets.
  • Branch circuits
  • Small appliances, including  microwave ovens, dishwashers, and garbage disposals
  • HVAC systems
  • In Air Void Applications of Tile Walls
  • The applications of NM-B are specified in Article 334 of NEC

The particular applications of NM-B in size 8/3 rated 40Amps include:

  • Electric Ranges and Ovens
  • HVAC Systems
  • Large Power Tools
  • Hot Water Heaters
  • Larger Sub-Panels

8/3 NM-B Standards:

  • ASTM B-3 and B-8
  • UL Standard 83
  • UL Standard 719
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

8/3 NM-B Construction:

Conductors:

The 8/3 cable has 3 conductors with a bare ground wire. The conductors are made of soft Stranded bare annealed copper.

Insulation:

The 8/3 NM-B cable has a polyvinyl chloride (PVC) insulation, making it perfect for harsh conditions. 

Jacket:

PVC jacket comes in yellow, orange, white, and black colors.

8/3 Romex Specifications:

  • Size AWG: 8
  • Weight per 1000 ft: 253 lbs
  • Conductors: 3
  • Number of Strands: 7
  • Insulation: PVC
  • Insulation Thickness: 35 mils

Compatible with Manufacturer

Southwire : Black : 639492



*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

FAQ's

What does NM-B Wire Mean?

"NM-B" wire stands for "Non-Metallic Type B." This is a specific type of electrical wire commonly used in residential indoor wiring.

What Does The B Stand For In NM-B Wire?

The letter "B" in NM-B wire indicates that the cable was designed for 90 degree C ampacity ratings. NM-B wire without B is an older type of an electrical cable that is no longer in use. The modern NM-B wire was introduced in 1984.

Can You Run Romex In Conduit?

NM-B wire can be run through conduit, despite any stereotypes that suggest otherwise. It is run in conduit in areas where it can be subjected to physical damage, such as exposed locations. Its typical indoor in-wall installations already protect it by its non-metallic sheathing.

Can Romex Be Exposed?

Romex NM-B wire can only be exposed under particular circumstances, such as one- and two-family dwellings, their attached or detached garages, and their storage buildings. This is specified in NEC 334.10 and 334.15. If exposed, the cable has to be protected from physical damage.

How to Strip Romex Wire?

To strip Romex wire, start by cutting away the outer jacket to expose the conductors. 

It's crucial not to damage the conductors beneath the jacket. A tool like the L'il Ripper Stripper is handy for this, as it can cut the jacket without harming the conductors. You can also use a utility knife, but you must be careful. 

Once the jacket is removed, decide how much insulation you want to strip off (usually about 1 inch). Insert the conductor into the right-sized notch in a wire stripper, squeeze the handles, and pull the insulation off the wire. Be cautious when stripping lamp cords made of stranded copper wire, as the individual strands are easily damaged​​.

How To Run Romex in the Attic?

Running NM-B Romex in the attic is acceptable, but it requires protection. If you run Romex in the attic, you should staple the cable or secure it with joists or rafters.

How To Splice Romex?

Splicing NM-B Romex is quite simple. You just have to:

  • Turn off power: Always start by turning off power to the circuit you're working on.
  • Strip wires: Remove the outer sheathing of the Romex cables at the point of splice and strip the insulation from the individual wires.
  • Align wires: Align the same-colored wires from each cable.
  • Twist wires together: Twist the ends of each set of similar wires together using pliers.
  • Secure with wire nuts: Place wire nuts over the twisted wire ends and twist until tight.
  • Insulate and protect: Insulate the splice with electrical tape and place it in a junction box.
  • Cover junction box: Cover the junction box with a solid cover plate.

The difference between splicing Romex and splicing other types of cables is that you have to splice the outer sheath first and then strip the insulation of individual conductors.

Can Romex Be Exposed In the Garage?

Romex NM-B Wire can only be run through bored holes between the studs as a protection.

Can You Use Romex In A Commercial Building?

Romex (NM cable) can be used in commercial buildings, but specific restrictions and requirements must be adhered to. According to the National Electrical Code (NEC) 334.12(A)(1), NM cable is not permitted as open runs above drop ceilings in non-dwelling occupancies. This means that Romex cannot be used in areas like above drop ceilings in commercial buildings. However, it may be used in industrial building open runs if installed with additional protection.

A building that uses Romex must be of type III, IV, or V construction. In buildings of combustible construction, Romex may not be used. Additionally, the local jurisdiction might have its prohibitions or restrictions on the use of Romex, regardless of the type of construction.

NM-B Romex may not be the best for commercial buildings as it lacks required specific fire-resistant ratings.

Can You Bury Romex?

No, you cannot run Romex underground or in conduit. Is the cable you are looking for an UF-B wire.

Is Romex Plenum-Rated?

NM-B Romex is not plenum-rated.

Reviews

Customer Reviews

Based on 35 reviews
100%
(35)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
Joao Reis

Great product. Fast delivery.

J
James
8/3 romex

Great insulation jacket, tightly wound inner wires, easy pull, easy termination.

S
Steven Jones
Excellent cable, low price

8/3 cable is excellent quality, cut exactly to the length requested, at a low price. Great deal.

T
Tim Spangler

Awesome people to deal with never a problem

T
Timothy Boudreaux
Great Deal

Great deal and helpful service

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460