18 AWG 36T Individual and Overall Shield Instrumentation Tray Cable VNTC TC-ER 600V
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
18 AWG 36T Individual and Overall Shield Instrumentation Tray Cable VNTC TC-ER 600V
Application:
• The cables can be used in trays, conduit, and wireways. They are sunlight resistant and suitable for direct burial. They are available with a PVC or CPE jacket.
Scope:
• This Instrumentation Cables is UL listed under Article 340 of the NEC and is suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be used in wet or dry locations and up to conductor temperatures of 90°C. The addition of nylon over the conductors provides excellent oil and gasoline protection.
• The individually shielded pairs and triads are completely isolated from each other by use of a polyester tape. This isolation assures maximum protection from crosstalk and common mode interference. An overall shield provides additional protection.
• The flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.
Also Known As:
18 AWG 36T Shielded VNTC Cable, 18 AWG 36T Instrumentation Cable, 600V VNTC Control Cable, 18 AWG 36T 600V Shielded Instrumentation Tray Cable, TC-ER Instrument Cable, VNTC Tray Cable, 18/36T 600V Shielded Control Cable.
Construction:
Class B, stranded per ASTM B-3 and ASTM B-8.
Conductors are type TFN listed under UL 62.
Available in tinned copper upon request.
Primary Insulation:
105°C rated PVC and nylon jacket
Shielding:
Each pair or triad with individual drain wire is shielded with aluminum /polyester tape. All are isolated with an additional polyester tape. Overall shield is helically applied with 100% coverage with a tinned copper drain wire.
Overall Jacket:
PVC (90°C rated)
Ripcord is applied under the jacket to facilitate stripping
Specifications:
• AWG: 18
• No. of Triads: 36
• Nominal Jacket Thickness (In): .082
• Nominal Outside Diameter (In): 1.421
• Pulling Tension (Pounds): 1705
• Nominal Weight 1000 FT (Pounds): 1279
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460