600-4C W/G Aluminum interlocked Armor AIA Copper Conductor Type MC Metal Clad PVC Jacket Power Cable

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
600-4C W/G Aluminum interlocked Armor AIA Copper Conductor Type MC Metal Clad PVC Jacket Power Cable
Application:
Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Silicone Free.
Also Known As:
600 MCM 600-4C W/G MC Cable, Aluminum interlocked armor MC cable, AIA copper conductor MC cable, 600 MCM PVC jacketed MC power cable, 4-conductor MC cable, 600V Type MC armored cable, XHHW-2 insulated MC cable, 600 MCM UL Type MC cable 600V.
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• UL 44 Thermoset-Insulated Wires and Cables
• UL 1569 Metal-Clad Cables
• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3 BLUE, 4-ORANGE)
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
Construction:
• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Insulation: Cross Linked Polyethylene (XLPE) Type XHHW-2
• Grounding Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Filler: Paper filler (cable size 8 & 6 uses Polypropylene filler)
• Binder: Polypropylene tape
• Armor: Aluminum Interlocked Armor (AIA)
• Overall Jacket: Polyvinyl Chloride (PVC) Jacket
Specifications:
• Size: 600 MCM
• Number of Conductor: 4
• Number of Strands: 61
• Diameter Over Conductor (inch): 0.865
• Insulation Thickness (Mil): 80
• Ground No. x AWG: 1 x 4/0
• Diameter Over Armor (inch): 2.798
• Jacket Thickness (mil): 80
• Approx. OD (In): 2.964
• Approx. Weight (Lbs/1000'Ft): 9698
• Min Bending Radius (In): 20.7
• Max Pull Tension lb: 15360
• Allowable Ampacity At 75°C (Amp): 336
• Allowable Ampacity At 90°C (Amp): 380
Compatiable with manufacturer |
Southwire | 672989 |
[short]
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460