6 Cores 6 mm² JIS C 3410 0.6/1KV (FA-)6PY Shipboard Flame Retardant Power Cable
Where are we? 4 Continents 9 Countries
Specification
-
No. of Cores : 6
-
Conductor Nominal Area : 6 mm²
-
Conductor Strand : 7/1.04 No./mm
-
Conductor Dia. : 3.12 mm
-
(FA-)5PY Nominal Dia. : 19.0 mm
-
(FA-)5PY Tolerance : 0.9 ±mm
-
Conductor Resistance (at 20°C) (Max) : 3.11 Ω/km
-
Insulation Resistanc e (at 20°C) (Min) : 800 ㏁ - km
-
Cable Weight : 0.4233
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
6 Cores 6 mm² JIS C 3410 0.6/1KV (FA-)6PY Shipboard Flame Retardant Power Cable
Allowable Ampacity For 6 Cores 6 mm² JIS C 3410 0.6/1KV (FA-)6PY Shipboard Flame Retardant Power Cable : 100 Amps
Application Standard:
- Design guide : JIS C 3410(2010)
- Flameretardant : IEC60332-1
: IEC 60332-3 Category A (FA-Cables Only)
- Cold Bend/Impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold TypeOnly)
- Max. Rated Conductor Temperature : 90℃
Also Known As:
Shipboard Cable, JIS C 3410 Cable, 0.6/1KV (FA-)5PY, Galvanized Steel, Flame Retardant Cable, PVC Cable, Tinned Annealed Copper
Construction :
Conductor :
-
Code : D, T,F 5, 6,10
- Stranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)
- A Suitable Tape May Be Applied On The Conductor
Insulation :
-
Code : P
- EPR As Per JIS C 3410(2010)
Cabling :
- Insulated Conductors Shall Be Cabled.
- Flame Retardant & Non-hygroscopic Fillers May Be Used.
- Suitable Tape(S) May Be Applied On The Cabled Core.
Sheath :
-
Code : Y
- PVC As Per JIS C3410(2010)
Armour :
-
Code : C
- Braid Of Galvanized Steel Wire(C)
-
Coverage Density : Min. 90%
Paint :
- The White Paint Shall Be Painted Uniformly On The Steel Wire Braid
- In Case Of PVC Protective Covering Cable, Paint Isdispensable.
Protective Covering :
-
Code : Y
- PVC As Per JIS C3410(2010)
- Protective Covering Color : Black
- Any Other Color May Be Applicable When Purchaser Required.
Core Identification:
No. of cores |
Without Earth core |
With Earthcore |
2C |
Black,White |
- |
3C / 2C+E |
Black,White,Red |
Black, White,G/Y |
4C / 3C+E |
Black,White,Red,Green |
Black, White, Red,G/Y |
5C And Over |
Black No. on White Insulation |
Black No. on White Insulation,G/Y |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.