2 AWG 3C + 3#20 AWG Ground Wire VFD Cable 600V/1000V
Three Conductor Variable Frequency Drive Cable 600V UL Type TC-ER / 1000V UL Type Motor Supply
Application:
Three Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The three conductor construction is suitable for applications that are generally dry with one-phase fault conditions, where an insulated ground is not required.
Conductors:
• 16AWG-4AWG: Stranded soft drawn tinned copper
• 2AWG and larger: Stranded soft drawn bare copper
Ground(S):
• 16AWG-4AWG: Stranded soft drawn tinned copper
• 2AWG and larger: Stranded soft drawn bare copper
Insulation:
• Cross-linked polyethylene (XLP) insulation
Shielding:
• 16AWG-4AWG: Aluminum/Mylar/Aluminum tape 100%
coverage & tinned copper braid
• 2AWG and larger: 0.005” helical bare copper tape shield with a
50% overlap
Jacket:
• Black polyvinyl chloride (PVC) jacket that is sunlight,
moisture, oil and abrasion resistant, and direct burial rated.
• Rated for use from -40°C to 90°C
Standards:
• UL 1277, Type TC-ER, Type XHHW-2
• UL approved as 1000V flexible motor supply cable
• UL listed as VFD or WTTC per UL 2277 for Flexible Motor Supply and Wind Turbine Tray Cables
• CSA FT-4 Vertical tray flame test
• CSA AWM I/II A/B singles
• CSA Type AWM per CSA standard C22.2 No. 210-11
• c(UL) CIC-TC per CSA standard C22.2 No. 239-09 & 230-09
• Meets UL 1202/1583 70,000 BTU flame test
• Meets ICEA T-29-520 210,000 BTU flame test
• Suitable for use in Class I Division II hazardous locations
• 90°C DRY/WET
• RoHS II & REACH compliant
Specification:
Part Number: 2-03VFD-3G
Conductor Size: 2 AWG
Conductor Stranding: 133
Ground Wire(s) Size: 3#6 AWG
Insulation Thickness: 0.045 Inches
Jacket Thickness: 0.080 Inches
Overall Diameter: 1.112 Inches
Weight ( Lbs/MFT ) : 1486 lbs
Compatible with Manufacturer |
|
Omni Cable : | VFD110203 |
Priority Wire & Cable : | 2-03VFD-3G |
Houston Wire & Cable : | HW191A00203 |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460