Product Information
Specification
5 Cores 1.0 mm² RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free and MUD Offshore Cable
Allowable Ampacity for 5 Cores 1.0 mm² RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free and MUD Offshore Cable: 100 Amps
Also Known As:
RFOU Cable, Low Voltage Cable, Power Lighting Cable, Offshore Cable, Flame Retardant Cable, Halogen Free Cable, MUD Cable, Marine Cable, Marine Shipyard Cable
Construction:
• Conductor: Stranded tinned anneaIed copper wires as per IEC 60228, CIass 2
• Insulation: EPR as per IEC 60092-360
• Cabling: - InsuIated cores shaII be cabIed
- FIame retardant & non-hygroscopic fiIIers may be used
- SuitabIe tape(s) may be appIied on the cabIed core
- A FiIIer may be appIied to obtain a circuIar CabIe
• Inner Covering: FIame retardant haIogen free thermoset compound
• Armor: - Braid of tinned copper wire (O) / bronze wire (B) /gaIvanized steeI wire (C)
- A suitabIe separator tape(s) may be appIied under/over the armor
• Sheath: - SHF2 as per IEC 60092-360
- Option: NEK 606 Category a,b,c,d Mud or oiI resistant
- Outer sheath coIor: BIack
Sheath Marking:
• e.g. : S.E.C. 0.6/1kV P1/P8 RFOU-M 2 X 70SQMM NEK 606 IEC 60332-3A MUD SEOUL Year Length
Core Identification:
|
|
|
1C | Off-White or BIack |
- |
2C | Off-White, BIack | - |
3C / 2C + E | Off-White, BIack, Red | Off-White, BIack, G/Y |
4C / 3C + E | Off-White, BIack, Red, BIue | Off-White, BIack, Red, G/Y |
5C / 4C + E | BIack No. On White InsuIation | Off-White, BIack, Red, BIue, G/Y |
6C and over | BIack No. On White InsuIation | BIack No. On white InsuIation, G/Y |
Application Standard:
• Design Guide: NEK-606& IEC 60092-353
• Flame Retardant: IEC 60332-1 & IEC 60332-3 Category A
• Halogen Content: IEC 60754-1, 0.5% ↓
• Cold bend / Impact: CSA C22.2 No. 2556 or IEC 60092-350 Annex.E Method 1 (-40/-35°C)
• Mud / Oil Resistant: NEK 606 (Category a,b,c,d)
• Smoke light Transmittance: : IEC 61034, 60% ↑
• Sunlight (UV) Resistant: UL 1581
Specification:
• No. of Cores: 5
• Conductor Nominal Area: 1.0 mm²
• Conductor Min. No. of Wires: 7 EA
• Conductor Max. Overall Dia: 1.4 mm
• Thickness of Insulation: 1.0 mm
• Thickness of Inner Covering: 1.0 mm
• Nominal Dia. Inner Covering: 10.9 mm
• Dia. of Wire for Armour: 0.3 mm
• Thickness of Sheath: 1.3 mm
• Overall Diameter Nominal: 15.0 mm
• Overall Diameter Tolerance: 0.9 ±mm
• Conductor Resistance (at 20°C) (Max.): 18.2 Ω/km
• Insulation Resistance (at 20°C) (Min.): 1490 MΩ-km
• Test Voltage: 3500 V/5min.
• Cable Weight: 0.254 Lbs/Ft