4-4 Delgado Duplex Aluminum Conductor Underground Direct Burial 600V URD

4-4 Delgado Duplex Aluminum Conductor Underground Direct Burial 600V URD
Roll over image to Zoom
4-4 Delgado Duplex Aluminum Conductor Underground Direct Burial 600V URD
Roll over image to Zoom
4-4 Delgado Duplex Aluminum Conductor Underground Direct Burial 600V URD
SKU: NNC1925X
duplex-aluminum-conductor-underground-direct-burial-1350-series-600v-urd

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.75 /FT
Sale price
$0.75 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

4-4 DELGADO DUPLEX ALUMINUM CONDUCTOR UNDERGROUND DIRECT BURIAL 600V URD

Allowable Ampacity for 4-4 Delgado Duplex Aluminum Conductor 600V URD direct burial: 125 Amps

Allowable Ampacity for 4-4 Delgado Duplex Aluminum Conductor 600V URD in duct: 90 Amps

Applications:

The 4-4 Delgado Duplex Aluminum URD Cable is designed for single-phase secondary power distribution in underground electrical systems. It is 600V-rated and suitable for direct burial or installation in ducts. Featuring two aluminum conductors and XLPE insulation, this cable is moisture-resistant, heat-resistant, and durable for outdoor use.

With a maximum operating temperature of 90°C, it performs reliably in both wet and dry environments. The duplex configuration, consisting of one phase conductor and one neutral, makes it ideal for single-phase service drops from transformers to buildings.

Specific Use Cases of 4-4 URD

  • Distributes single-phase power to service meters in residential and rural areas.
  • Supplies underground power to small commercial buildings and utility poles.
  • Provides electricity to single-family homes, mobile homes, and farm buildings.
  • Used in street lighting circuits and outdoor power installations.
  • Supports temporary power for construction sites and emergency setups.

Also Known As:

4-4 delgado aluminum urd cable, 4-4 delgado urd direct burial cable, 4-4 delgado two conductor cable, 4-4 delgado direct burial electrical cable, 4-4 delgado direct burial power cable, 4-4 delgado aluminum direct burial cable, 4-4 delgado 2 conductor power cable, 4-4 delgado two conductor.

Standards:

  • ICEA S-105-6922

  • ASTM B-230 approval

  • ASTM B-609

  • ASM B-231

  • ASTM B-901

  • Accepted by RUS

  • Federal Specification J-C- 30 B

Construction

Conductors:

Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital.

Aluminum 600 V URD cable has its two conductors coupled together and surface printing helps in identification of the conductors. The color for the neutral conductor is always yellow stripped.

Insulation:

Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.

Specifications:

    • Size AWG: 4

    • Stranding: 7/w

    • Insulation Thickness (mils): 60

    • Neutral Size AWG: 4

    • Single Phase Conductor Inches: 0.345

    • O.D. Inches:  0.690

    • Weight lbs./1000ft: 129 lbs

    • Ampacity: Direct burial: 125 Amps

    • Ampacity: In duct: 90 Amps


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460

Win an Exclusive prize!

Enter your full name and email to spin the wheel for a chance to win

Powered by CareCart