4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable
nassaunationalcable.com/products/4-0-0-4-feeder
Items in Cart ()
View cart

4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable

4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable
SKU: NNC1676X
aluminum-mobile-home-feeder-cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$4.77 /FT
Sale price
$4.77 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 57 reviews
88%
(50)
7%
(4)
0%
(0)
2%
(1)
4%
(2)
T
Todd

Great communication, fast shipping

J
John

Great price, rapid shipping

Z
Zhakry Treadway
Ordered wire for my house.

Very satisfied with my order, delivered on time and the correct amount! Will use them again if I need any wire.

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Direct Burial Cable 600V

Allowable Ampacity for 4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable: 200 Amps

Applications:

4/0-4/0-2/0-4 Aluminum Mobile Home Feeder Cable is a 200-amp, 600V-rated service entrance cable designed to supply power from a utility meter base to the main distribution panel in a mobile or manufactured home. It is also suitable as a high-capacity feeder cable for subpanels in modular buildings, large residential units, detached garages, shops, and light commercial installations.

This cable is approved for direct burial when marked USE-2 and may also be installed in conduits, ducts, or raceways in wet or dry locations. Its cross-linked polyethylene (XLP) insulation provides excellent durability and resistance to moisture, abrasion, and chemicals, making it ideal for underground and outdoor use.

In size 4/0-4/0-2/0-4, the cable is commonly used to deliver 200 amps of power to subpanels supporting multiple branch circuits, heavy-duty appliances, HVAC systems, and general-purpose loads in high-demand environments.

Also Known As:

4/0-4/0-2/0-4 aluminum cable, 4/0-4/0-2/0-4 aluminum wire, 4/0-4/0-2/0-4 mobile home feeder cable, 4/0-4/0-2/0-4 underground feeder cable, 4/0-4/0-2/0-4 service entrance cable, 4/0-4/0-2/0-4 electrical feeder cable, 4/0-4/0-2/0-4 power feeder cable, 4/0-4/0-2/0-4 MHF cable, 200 amp mobile home feeder wire, 4/0-4/0-2/0-4 direct burial wire.

Standards:

  • Ampacities based on National Electric Code, 2005n edition, section 310-15 

  • National Electric Code (NEC)

  • UL 44 for types RHH & RHW-2 

  • UL 854 for type USE-2

  • ASTM standards B 800, B 801 

  • Sunlight resistant 

  • RUS ACCEPTED

Construction

Conductors:

The 4/0-4/0-2/0-4 cable includes two 4/0 AWG phase conductors, one 2/0 AWG neutral, and one 4 AWG ground. All conductors are compact stranded 8000 series aluminum per ASTM B-800/B-801.

Insulation:

It has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP-insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.

Specifications:

  • Cable Construction: 4/0-4/0-2/0-4

  • Phase Conductor; Insulation (mils): 80

  • Insul. Phase Conductor; Diameter (inches): 0.635

  • Insul. Grounded (Neutral) Conductor; Diameter Inches: 0.540

  • Insul. Equipment Grounding Conductor; Diameter Inches: 0.335

  • Cable Diameter Inches: 1.540

  • New Weight lb/1000FT: 778 lbs

  • Ampacity: 200 Amps

Compatible with Manufacturer

Priority Wire & Cable : 4/0-04ALUM-MHF-R
Houston Wire & Cable : HW023A40204
Southwire : 30161401
Omni Cable : MHF4/02C-2/0-4


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What does 4/0-4/0-4/0-2/0 AL MHF mean?

Two 4/0 AWG aluminum hot conductors, one 4/0 AWG aluminum insulated neutral, and one 2/0 AWG aluminum insulated equipment grounding conductor. All four conductors are individually insulated, rated 600V, with USE-2 or XHHW-2 insulation.

What size MHF do I need for 200A service?

4/0-4/0-4/0-2/0 aluminum for a 200A dwelling service under the NEC 310.12 reduced-sizing rule. For non-dwelling 200A feeders where that rule does not apply, use 250 MCM aluminum or 4/0 copper. Verify terminations at both ends are rated for the conductor size and material.

What is Mobile Home Feeder (MHF) cable?

A 4-conductor aluminum cable for feeding power from a service panel to a mobile or manufactured home. Modern MHF uses USE-2 or XHHW-2 conductor insulation, both listed for direct burial and wet locations. The "four conductor, all insulated" construction sets it apart from standard SER, which usually has a bare ground.

What amp rating does 4/0-4/0-4/0-2/0 aluminum MHF support?

For a residential dwelling service or main power feeder to a dwelling, 4/0 aluminum is rated for 200A under the reduced-sizing allowance in NEC 310.12. For non-dwelling applications, the standard 75°C ampacity from NEC 310.16 applies: 4/0 AWG aluminum is rated 180A at 75°C. The 2/0 equipment grounding conductor is sized per NEC Table 250.122.

Is 4/0-4/0-4/0-2/0 MHF cable rated for direct burial?

Yes. The individual conductors inside standard MHF are USE-2 or XHHW-2, both listed for direct burial in wet locations. Follow NEC 300.5 for burial depth: 24 inches for direct-buried residential feeders under 600V, 18 inches under a concrete slab, and shallower depths where protected by conduit.

Does MHF cable satisfy the NEC 4-wire feeder requirement for a separate structure?

Yes. Since 2008, NEC 250.32 has required a 4-wire feeder to a separate structure, with two hots, an insulated neutral, and a separate equipment ground, with the neutral and ground bonded only at the main service disconnect. MHF is built exactly this way. You still need a grounding electrode (typically a ground rod, or two rods 6 ft apart if a single rod does not achieve 25 ohms) at the second structure.

Do I need a separate ground rod at the mobile home end of the feeder?

Yes. NEC 250.32 requires a grounding electrode at the second structure. For mobile homes, this is typically a driven ground rod (or two rods 6 ft apart if a single rod does not achieve 25 ohms). The neutral and equipment ground must remain separated at the mobile home service equipment, since bonding happens only at the main service disconnect in the main structure. NEC 550 covers mobile home wiring specifically.

Can I use MHF cable inside conduit for the run to a mobile home?

Yes. The conductors inside MHF are USE-2 or XHHW-2, both suitable for wet locations and installation in underground conduit. Some electricians prefer to pull individual XHHW-2 or USE-2 conductors through the conduit instead of the MHF assembly, because loose conductors are easier to pull and take up less conduit fill area. Either approach is code-compliant.

How far can I run 4/0-4/0-4/0-2/0 MHF for 200A service?

Voltage drop, not ampacity, is the sizing limit at long distances. Rule of thumb for a 200A load on 4/0 aluminum at 240V single phase, keeping voltage drop under 3%: about 175 to 200 ft. For runs beyond 300 ft, upsize to 250 MCM or 350 MCM. Do the actual voltage-drop calculation for the specific load and run length before ordering.

What voltage drop should I expect on 4/0-4/0-4/0-2/0 aluminum MHF?

At 200A load, 240V single phase, on 4/0 aluminum, expected voltage drop is roughly 3% at 200 ft, 5% at 325 ft, and 7% at 455 ft. Standard practice keeps total voltage drop (feeder plus branch circuits) under 5%, with the feeder itself under 3%. Use a proper calculation with the actual load current before ordering.

Reviews

Customer Reviews

Based on 57 reviews
88%
(50)
7%
(4)
0%
(0)
2%
(1)
4%
(2)
T
Todd

Great communication, fast shipping

J
John

Great price, rapid shipping

Z
Zhakry Treadway
Ordered wire for my house.

Very satisfied with my order, delivered on time and the correct amount! Will use them again if I need any wire.

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460