16 AWG 50T Unshielded Triads with Overall Shield PLTC Instrumentation Tray Cable PVC/CPE 300V
Application:
• The cables can be used in raceways or, when provided with a messenger, for aerial application. When increased mechanical, chemical, or environmental protection is required, a hermetically sealed aluminum tape or copper tape armor with an additional PCV or CPE jacket can be provided.
• PLTC type Instrumentation Cable can be used in type CL3 or CL2 applications.
• Cable is suitable for use in Class I Division II hazardous locations.
• Cable is UL approved for Sunlight Resistant and Direct Burial Applications.
• Recommended Operating Voltage: 300V
Scope:
• These Instrumentation Cables are UL listed under Article 725 of the NEC and are suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be used in wet or dry locations and up to conductor temperatures of 105°C.
• The flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.
Also Known As:
16 AWG 50T PLTC Cable, 16 AWG 50T Instrumentation Cable, 300V PLTC Tray Cable, 16 AWG 50T PVC/CPE 300V Instrumentation Tray Cable, 16 AWG 50T PVC/CPE Instrument Cable, PLTC Tray Cable, 16/50T PVC/CPE 300V Shield Instrumentation Tray, PVC Cable.
Construction:
Class B, stranded per ASTM B-3 and ASTM B-8
Triads are twisted with staggered lays to reduce crosstalk.
Primary Insulation:
105°C rated PVC
Thickness: .015" nominal thickness
Overall Shield:
Overall shield is helically applied with 100% coverage with a tinned copper
drain wire
Overall Jacket:
PVC (105°C rated) or CPE (90°C rated)
Ripcord is applied under the jacket to facilitate stripping.
Standards:
UL listed as type PLTC & CL3 per UL standard 13 as type ITC per UL standard 2250.
Meets IEEE 1202 flame test.
All materials used in the manufacture of this cable are RoHS compliant.
Specifications:
• AWG: 16
• No. of Triads: 50
• Nominal Jacket Thickness (In): .092
• Nominal Outside Diameter (In): 1.681
• Pulling Tension (Pounds): 3117
• Nominal Weight 1000 FT (Pounds): 1923
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet