Electri Flexible Conduits Shield Galvanized Steel Type HFSLA Liquidtight Jacket Zero Halogen PUR
Select a Gauge
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Name | Length | Price (Per FT.) | Action | |
---|---|---|---|---|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
$531.70 |
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
$276.50 |
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
Product Information
Specification
Application:
- Meets the requirements of Bombardier SMP 800-C for Toxic Gas Generation.
- Meets the requirements of both ASTM E162 for Flame Spread and ASTM E662 for Smoke Generation.
This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI/NFPA-70)
- Suitable as an equipment grounding conductor per Article 250.118(6). Larger sizes require separate grounding conductor.
- Suitable for use in hazardous locations: Class I, Div. 2 and Classes II and III.
- PVC jacket is resistant to a wide variety of oils, acids, alkaline and ultraviolet light.
- Accepts Standard Metallic Liquidtight Fittings
- Designed for wiring applications requiring shielding effectiveness from Electromagnetic and Radio Frequency Interference (EMI/RFI)
Also Know As:
Electri Flexible Conduits, Liquidtight Jacket, Type HFSLA , Jacketed Metallic, Galvanized Steel, Type LA, Flexible PUR Conduits
Combustion & Flammability Properties
Combustion & Flammability
- Vertical Burn (Material)
- Vertical Burn (Conduit)
- Oxygen Index %
- Flame Spread Index
- Smoke Generation (Flaming)
- Smoke Generation (Non-Flaming)
- Toxic Gas Generation
- Toxicity Index
Test:
- UL94
- UL360
- D2863
- ASTM E162
- ASTM E662 (NFPA 258)
- ASTM E662 (NFPA 258)
- BOMBARDIER SMP 800-C
- NES 713
Value:
- V-0 Rating; No Flaming Drips
- Pass; No Flaming Drips
- 28.5
- 25; No Flaming Drips
- Ds 41@1.5 Min/Ds 113@4.0 Min
- Ds 4@1.5 Min/Ds 19@4.0 Min
- Pass
- 3.9
Markets:
Aerospace, Cell Towers, Data Centers, Defense, Healthcare, Renewable Energy, Ship Building, Telecommunications
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460