Draka LMC04350 350 MCM 4C Lifeline MC Bare Stranded Copper Unjacketed Two Hour Fire Resistive Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Draka LMC04350 350 MCM 4C Lifeline MC Bare Stranded Copper Unjacketed Two Hour Fire Resistive Cable
Allowable Ampacity for Draka LMC04350 350 MCM 4C Lifeline MC Bare Stranded Copper Unjacketed Two Hour Fire Resistive Cable: 100 Amps
Applications:
Lifeline® MC fire resistive cables were designed to meet and have successfully passed the two-hour fire rating certification test per UL 2196, Standard for Tests for Fire Resistive Cables.
Lifeline® MC Cables can be used in the following applications to provide survivability during a fire: - Tall Buildings - Fire Pumps - Emergency Feeder Cables - Ventilating Fans - Stairwell Pressurization - Exit Lighting - Elevators / OEO - Emergency lighting for roadway and transit tunnels when cables include optional LSZH jacket over armor Lifeline® MC Cables are preferred over Mineral Insulated (MI) cables, concrete encasement or the construction of fire rated assemblies based on the facts that Lifeline® MC Cables are less costly and easier to install for many applications. Fire resistive cables are required per NFPA 70/NEC, Articles 517, 695, 700, 708, 728 and 760 as well as NFPA 72 and NFPA 101.
Also Known as:
Metal Clad Cable, Bare Copper Cable, MC Unjacketed Cables, Fire Resistive Cable, Draka Lifeline MC Cable, LMC04350
Specifications and Ratings:
• Listed to UL 1569, Metal Clad Cables, as the following type:
• Type MC 600 Volt, Rated 90°C
• For Wet Locations
• For Cable Tray Use IEEE 1202/ FT4 Rated, ST1 Limited Smoke
• Classified to UL 2196, Standard for Tests for Fire Resistive Cables, for two-hours installations
• Electrical Circuit Integrity System (FHIT) No. 50 of the UL Fire Resistance Directory
• NFPA 70, NFPA 101 compliant
• Corrugated Copper Armor meets Equipment Grounding Conductor requirements of NEC Table 250.122
Design Parameters:
• CONDUCTORS: Bare stranded copper, 14 AWG through 600 kcmil
• INSULATION: Ceramifiable Silicone Zero Halogen (LSZH)
• INNER BINDER JACKET: Ceramifiable Silicone Zero Halogen (LSZH)
• ARMOR: Continuously Welded and Corrugated Copper
• IDENTIFICATION: Lifeline® MC Unjacketed Cables are marked as follows: DRAKA MA P/N [########] [X]/C [Y] LIFELINE (UL) E66840T MC-ST1 600V 90C WET LOCS FOR CT USE IEEE 1202/FT4 ST1 (UL) R19359 FRR 2HR UL 2196 ELECTRIC CIRCUIT INTEGRITY SYSTEM FHIT#50 480V UTILIZATION (MONTH/YEAR) (SEQUENTIAL FOOTAGE)
Notes: [#] is cable part number [X] is the number of conductors [Y] is the size of the cable in AWG or kcmil
Specification:
• Size AWG: 350
• Number of Cond: 4
• Nominal Core Diameter (in): 2.26
• Nominal Armor Diameter (in): 2.72
• Ampacity* 75°C Amps: 310
• Ampacity* 90°C Amps: 350
• Net Weight: 4.50 lbs per ft
• Part Number: LMC04350