Belden 27614A 18 AWG 50 Conductor Unshielded BC E2 UL Control 600V Type TC Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Introduction:
Belden offers a wide selection of UL-rated 600V Tray Cable for a variety of control applications. Multi-conductor versions are available as standards from 18 to 4/0 AWG. These are unshielded and shielded versions that come with various insulation and jacket combinations. These TC cables are installed in cable trays, ducts and conduit and can be used in direct burial applications. They are extensively used in manufacturing facilities, especially in the process industries such as petrochemical, steel, pulp and paper, cement and mining. These flexible, space efficient cables can be substantially more economical than traditional wiring methods.
Construction:
Soft annealed bare or tinned copper conductors, with various insulation and jacketing options as seen in chart below.
Application:
These cables are suitable for installation in wet or dry locations. Cable jackets are resistant to sunlight, moisture and vapor penetration. The cables can be used in raceways (supported by messenger wire), outdoor applications and direct burial applications.
Unshielded:
Cabled non-shielded conductors provide a minimal O.D. allowing greater tray and conduit fill. Non-shielded control cable may be utilized when recommended by the equipment manufacturer and used in a metallic conduit.
Specifications:
• UL Subject 1277 Type TC and TC-ER
• XLP/Haloarrest (thermoplastic) jacketed cables are UL 1277 TC-LS rated
• XLP/HaloarrestXLink™-1 and -2 are TC-ER rated
• UL Subject 1424 (per outline for NPLF requirements dated May 3, 1979)
• UL 1685 (UL 1581) Vertical Flame Test
• Approved for cable tray use in Class 1,Division 2 areas, per NEC Articles 340, 318 and 501, and for Class 1 circuits as permitted in Article 725
• PVC-Nylon/PVC, XLP/PVC and XLP/CPE constructed cables meet IEEE 1202/IEEE 383-2003/FT4 (70,000 BTU/hr) Flame Test
AWG: | 18 |
No. of Conductors: | 50 |
Stranding: | 7x26 |
Conductor Material: | BC - Bare Copper |
Insulation Material: | PVC/Nylon - Polyvinyl Chloride/Nylon Skin |
Insulation Nominal Diameter: | 0.088 in |
Outer Jacket Material: | PVC - Polyvinyl Chloride |
Temperature Range: | -30°C To +75 °C Dry/90°C Wet |
Voltage: | 600 V RMS/150 V RMS |
Weight: | 511 lbs/1000ft |
Plenum (Y/N): | No |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.