Belden 1043A 16 AWG 16 Pair BC Individually Overall Shield PVC/Nylon Insulation 600V Tray Cable
Description:
• Belden 1043A 16 AWG pairs stranded (7x24) bare copper conductors, twisted pairs, PVC/Nylon insulation, individually shielded plus an overall Beldfoil shield (100% coverage), PVC jacket.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Applications:
• UL Subject 1277 TC
• UL 1685 (UL 1581) Vertical Tray Flame
• NEC Type TC Listed, which is approved for cable tray use in Class 1, Division 2 areas, per NEC Articles 340, 318 and 501 and for Class 1 circuits as permitted in Article 725
• PVC-nylon/PVC constructions are NEC Type NPLF Listed, which is approved for use in Non Power-Limited Fire Protective Signaling circuits, per NEC Article 760
• PVC-Nylon/PVC, XLP/PVC and XLP/CPE constructed cables meet IEEE 1202/IEEE 383-2003/FT4 (70,000 BTU) Flame Test
• XLP/Haloarrest® (thermoplastic) cables are UL 1277 TC-LS rated
• XLP/HaloarrestXLink™-1 and -2 are TC-ER rated
TC-ER Rated Cables:
• Belden offers all PVC-nylon/ PVC, XLP/PVC and XLP/CPE jacketed tray cables with a TC-ER (Exposed Run) rating.
• Per NEC Article 336, a TC-ER rated cable may be installed in an industrial establishment between a cable tray and the utilization equipment or device.
• A TC-ER rated cable must meet the crush and impact requirements of UL Type MC cable. By eliminating the need for metal conduit and/or armor, using a TC-ER rated cable results in savings in both installation and maintenance.
Specifications:
Conductor Size AWG: | 16AWG |
Conductor Material: | Bare Copper |
Outside Diameter: | 1.035in |
Jacket Color: | Black |
Jacket Material: | PVC (Polyvinyl Chloride) |
Manufacturer Equivalents |
|
Alpha Wire : | Black : M8746160 |
Belden : | Black : 1043A 0102500 |
Omni Cable : | Black : BEL1043A |
Wirexpress : | Black : 2AS-1616SPOS-B |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.