8/4 Stranded Metal Clad MC Copper Conductor W/G 600V Aluminum Armored Cable

8/4 Stranded Metal Clad MC Copper Conductor W/G 600V Aluminum Armored Cable
Roll over image to Zoom

8/4 Stranded Metal Clad MC Copper Conductor W/G 600V Aluminum Armored Cable

SKU: NNC3822X
metal-clad-stranded-solid-mc-copper-conductor-w-g-aluminum-armored-cable-600v

Select a Gauge

8/4 Stranded Metal Clad MC Copper Conductor W/G 600V Aluminum Armored Cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$6.00
Sale price
$4.25 /FT 29% off
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

8/4 Stranded Metal Clad MC Copper Conductor W/G 600V Aluminum Armored Cable

Applications:

The metal clad cable is an electrical wire designed for use in power lines not exceeding 600 Volts. The MC wire has an operational temperature rating of up to 90°C in dry locations. The cable is armored with an aluminum interlocking strip, which offers great mechanical protection. The MC aluminum armored wire also has a green insulated grounding conductor. This electrical cable is lightweight and therefore, not labor-intensive, which makes it a cost-effective option over other piped wire installations. 

Also Known As:

8/4 metal clad cable, 8/4 aluminum armored cable, 8/4 mc cable, 8/4 mc wire, 8/4 mc cable wiring, 8/4 armored wire, 8/4 armoured electrical cable, 8/4 mc electrical wire, 8/4 fire alarm mc cable, 8/4 flexible armored cable, 8/4 armored cable wiring, 8/4 metal clad cable type mc, 8/4 armored fire alarm cable.

Standards:

  • UL 83, 1479, 1569, 1581, 2556, File Reference E80042
  • NEC® 230.43, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645
  • Federal Specification A-A-59544 (formerly J-C-30B)
  • Meets all applicable OSHA and HUD Requirements
  • May be surface mounted, fished and/or embedded in plaster
  • Cable Tray Rated, install per NEC®
  • UL Classified 1, 2, and 3 hour through (Fire) penetration product, R-14141
  • Environmental Air-Handling Space Installation per NEC® 300.22(C)
  • RoHS Compliant
  • Made in USA of US and/or imported materials

Construction

Conductors:

This aluminum armored cable has a stranded or solid copper conductor. Copper is the most common material used in electrical wires and cables, which is mostly because it has amazing electrical properties and is cheaper compared to other metals. The stranding enhances its flexibility and enables it to carry more current.

Conductor Insulation:

Conductor insulation for this metal clad cable wiring is THHN/THWN: THHN stands for thermoplastic high heat-resistant nylon, which is known for versatility and durability. The double marking THHN/THWN indicates that the electrical wire is suitable for wet and dry conditions equally. Additionally, this makes the cable resistant to corrosion, excessive dryness, and the impact of chemicals. 

Armor:

The interlocking aluminum strip serves as armor applied over the cabled together conductors, with the polypropylene tape wrapped around the assembly. The armor makes the MC cable highly resistant from crush and rodent as well as ensures installation with no extra inner duct or conduit.

Specifications:

  • Trade Size: 8-4 Stranded
  • Grounding Conductor AWG: 10
  • Length (feet): Coil: 125’
  • Length (feet): Reel: 500’
  • Approx. Weight/1000Feet (lbs.): 415
  • Armor Minimum O.D. (inches): 0.835

Compatible with Manufacturer

Priority Wire & Cable : 8-04MCA/STR


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

FAQ's

What are the particular applications of 8/4 MC cable?

For an 8/4 MC cable with four insulated conductors (three hots and a neutral) and a grounding wire, applications are:

  • Three-phase power applications
  • Large appliances and systems
  • Backup generators
  • Subpanels
  • Complex electrical installations include buildings with specialized equipment or detailed control systems.

What is MC cable?

MC cable, or metal-clad cable, is an electrical cable with one or more conductors enclosed in a metallic sheath. It's used for power distribution and control in various settings and protects against physical damage and electromagnetic interference.

Can MC cable be exposed?

Thanks to their metal armor, metal-clad (MC) cables can be exposed as per the National Electrical Code (NEC). The armor serves as an equipment grounding conductor.
MC cable can be exposed in dry, damp, or wet locations depending on the MC cable used. The cable's outer jacket contains information about suitable environments to expose the cable. While MC cable is durable, it should not be installed in areas subject to physical damage unless protected by conduit or other means.
MC cable must be adequately supported and secured according to NEC guidelines. MC cable must be supported at least every 6 feet for horizontal runs. Support can be used for MC cables, including straps, staples, ties, and standoff brackets.

How to strip MC cable?

Stripping MC (Metal-Clad) cable involves removing a portion of the metal sheath to expose the insulated wires without damaging them. Here's a step-by-step guide:

Tools Needed:

  • MC cable cutter or a hacksaw
  • Cable stripping tool designed for MC cable or a utility knife
  • Pliers
  • Wire strippers for the internal wires
  • Safety glasses and gloves for protection

Steps to Strip MC Cable:

  1. Measure and Mark: Determine the length of the cable sheath you need to remove. Mark this length on the cable sheath.
  2. Cut the Sheath: If you're using an MC cable stripper, adjust it to the size of your cable, place it around the marked area, and rotate it around the cable to score the sheath. If you're using a utility knife, gently score around the circumference of the cable at the mark. Be careful not to cut too deeply to avoid damaging the internal wires.
  3. Bend and Snap: Bend the cable back and forth at the scored line. This helps break the sheath at the score without damaging the wires inside. The sheath might not completely separate from an MC cable like some other cable types, but the bending will help loosen it.
  4. Remove the Sheath: Use pliers to twist and pull the scored section of the sheath away from the cable. This exposes the internal insulated wires. For cables with a tightly fitting sheath, you may need to make a longitudinal cut to peel it back along the sheath. Again, be cautious not to nick the insulation of the inner wires.
  5. Install Anti-Short Bushing: Slide an anti-short bushing (a red head) over the exposed wires and into the end of the remaining sheath. This protects the wire insulation from being cut by the sharp edges of the metal sheath.
  6. Strip Individual Wires: Use wire strippers to strip the insulation from the end of each internal wire as needed for your connections, typically about 3/4 inch. Use the correct size slot on your wire strippers to avoid damaging the wire.

Can you use MC cable outside?

Yes, you can use Metal-Clad (MC) cable outside, but it has to be a subtype with a waterproof and UV-resistant jacket. If corrosion is a concern, the armor has to be corrosion-resistant.

Is MC cable plenum-rated?

MC cable can be plenum-rated if it is designed to be installed in plenum spaces in commercial or industrial buildings. A plenum-rated MC cable will have a "PL" or similar marking on the jacket. Examples of plenum-rated MC cables include healthcare facility MC cables, and LSZH MC cables. MC cables for residential use are not plenum-rated.

Can you run MC cable in conduit?

While MC cable's metal sheath already protects the wires, you can run MC cable in conduit in certain circumstances. Running MC cable through the conduit can offer additional protection in areas where the cable might be subject to physical damage. Running MC cable through the conduit can also be helpful in transitioning between different types of environments, such as from an indoor to an outdoor setting, where additional protection might be necessary.

How many MC cables can you bundle together?

In general, you can bundle up to 20 current carrying-conductors together. Note that the neutral wire is considered a current-carrying conductor and must be included in the count when bundling wires.
Also note that when cables are bundled together for more than 24 inches, the NEC requires that the ampacity of each conductor be derated according to tables provided in the NEC (typically found in NEC Table 310.15(B)(3)(a)). The derating factor depends on the number of current-carrying conductors in the bundle. If you want to avoid derating, bundle for at most 24 inches.
The physical size of the bundle should not be so large as to impede heat dissipation or make installation difficult.

Is MC cable weatherproof?

Standard MC cable is usually not waterproof. MC Cable with a PVC Jacket (MC-HL or Type MC-PCS) can be used outdoors, and some MC cables are corrosion and UV-resistant and rated for direct burial.

Are anti-shorts required for MC cable?

Anti-short bushings, also known as "redheads," are small plastic inserts designed to protect the insulation of wires from the sharp edges of the metal armor in Metal-Clad (MC) cable. While the National Electrical Code (NEC) does not explicitly require anti-short bushings for MC cable, they are considered a best practice. Many manufacturers and electrical professionals strongly recommend them for safety reasons.

Can I use MC cable in a residential setting?

Yes, you can use Metal-Clad (MC) cable in residential applications, including construction.

Can MC cable be surface-mounted?

Yes, MC cable can be surface-mounted in the basement, warehouses, and other locations where running cables in walls is not a suitable practice.
The National Electrical Code (NEC) specifies that MC cable must be regularly supported and secured within 12 inches of every cable termination. The exact spacing can vary depending on the installation specifics and local codes, but a common requirement is every 6 feet for horizontal runs. Cable straps, staples, or similar fittings suitable for MC cable should be used to secure the cable to the surface.