6 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
6 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable
Allowable Ampacity For 6 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable : 100 Amps
Application Standard :
- • Design Guide : IEC 60092-350 & IEC60092-376
- • Flame Retardant : IEC60332-1
: IEC 60332-3 Category A (FA-Cables Only) - • Cold Bend/Impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold Type Only)
- • Max. Rated Conductor Temperature : 90℃
Also Known As :
Shipboard Cable, JIS C 3410 Cable, RCOP(OS) Cable, Asian Shipyard Cable, Flame Retardant Cable, Annealed Copper Wire, Instrumentation Cable, Japenese Industrial Cable, Marine Shipyard Cable
Construction :
Conductor :
- • Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2
Insulation :
- • Code : R
- • EPR As Per IEC 60092-351
Twisting :
- • Two/Three Insulated Cores Shall Be Twisted Together To Form A Pair/Triad
Cabling :
- • Twisted Pairs/Triads Shall Be Cabled
- • Flame Retardant & Non-Hygroscopic Fillers May Be Used
- • Suitable Tape(s) May Be Applied On The Cabled Core
- • A Filler May Be Applied To Obtain A Circular Cable
Collective Screen :
- • Code : (OS)
- • AL/PS Tape + Tinned Copper Drain Wire (0.75mm2)
- • A Suitable Tape May Be Applied On The Collective Screen
Inner Sheath :
- • Code : C
- • SE1 As Per IEC60092-359
Armour :
- • Code : O
- • Braid Of Plain Annealed Copper Wires
- • Coverage Density Is Minimum 90%
Outer Sheath :
- • Code : P
- • ST2 (PVC) As Per IEC 60092-359
- • Outer Sheath Color : Grey (For Non-IS Type) Or Blue (For IS Type)
Core Identification :
- • Printed Pair/Triad Number And Alphabet Letter On The White Insulation
- • ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
- • 2T : (1A, 1B, 1C), (2A, 2B, 2C)
Specification :
- • No. Of Units : 6T
- • Conductor Nominal Area : 1.0 mm²
- • Conductor Strand : 7/0.43 No./mm
- • Conductor Dia. : 1.29 mm
- • Nominal Dia. Inner Sheath : 19.1 mm
- • Overall Diameter Nominal : 23.3 mm
- • Overall Diameter Tolerance : 1.2 ±mm
- • Conductor Resistance (at 20°C) (Max) : 19.3 Ω/km
- • Insulation Resistance (at 20°C) (Min) : 20 Ω/km
- • Cable Weight : 0.5714 lbs
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460