500 MCM 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
500 MCM 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket
Application:
The 35KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.
Also known as:
500 MCM 3C 35kV Medium Voltage Cable, 500MCM 3C 35kV MV-105 Cable, 500 MCM 3C 3-Conductor 35kV Copper Cable, 500 MCM 3C 35kV Armored Power Cable, 500 MCM 3C ARMOR-X Cable, 500 MCM 3C 133% Insulation Level Cable, 500-3C NL-EPR Insulated Cable, 500-3C Copper Tape Shielded Cable, 500-3C Continuous Corrugated Welded Armor Cable, 500-3C CCW Armored Cable, 500-3C 35kV Direct Burial Cable, 500-3C MV-105 Tray Cable, MC-HL Medium Voltage Cable, 500-3C Hazardous Location Power Cable, 500-3C Orange PVC Jacketed MV Cable.
Constructions:
Conductor: Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)
Conductor Shield: Semi-conducting cross-linked copolymer
Insulation: 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)
Filler: Wax paper filler
Binder: Polypropylene tape
Armor: ARMOR-X Continuous Corrugated Welded Armor
Overall Jacket: Polyvinyl Chloride (PVC)
Standards :
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
• UL 1072 Medium-Voltage Power Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
Specifications:
Conductor size: 500 MCM
No of Strands: 37
Diameter Over Conductor: 0.789 inch
Diameter Over Insulation: 1.652 inch
Diameter Over Insulation Shield: 1.712 inch
Ground: 1x1 AWG
Diameter Over armor: 4.196 inch
Jacket Thickness: 85 mil
Approx. OD: 4.366 inch
Copper Weight (lb/1000ft): 5333
Approx. Weight (lb/1000ft): 11077
Max Pull Tension (lb): 12000
Min Bending Radius: 31.0 inch
|
Compatible with Manufacturer |
|
| Southwire | 584304 |
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460