4/3 CONTINUOUSLY WELDED ARMOR CABLE MV-105 MC-HL SHIELDED EPR INSULATION 5kV
Applications:
The metal clad cable is an electrical wire that is often used in severe and hazardous environments where the maximum conductor and electrostatic interference protection are needed. It can continuously operate in temperatures of up to 105°C in both wet and dry conditions. However, in case of emergency overload or short circuits, this mc wire can operate in temperatures up to 140°C and 250°C respectively. This electrical wire has a voltage rating of 5,000V, which makes it suitable for lightweight power applications.
Also Known As:
4/3 instrumentation cable, 4 3 armoured instrument cable, 4 3 metal clad cable, 4 3 aluminum armored cable, 4 3 mc cable, 4 3 mc wire, 4 3 mc cable wiring, 4 3 mc electrical wire.
Standards:
- UL listed, NEC Type MV-105 and Type MC, UL Standard 1072
- Single conductors are qualified per AEIC CS8
- UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test
- ICEA 70,000 BTU/hr and 210,000 BTU/hr Flame Test
- IEEE 1202 Flame Test
Construction
Conductors:
Instrumentation cable conductors are made from soft bare annealed copper in accordance with ASTM B-3, compact Class B stranding per ASTM B-496, with a semi-conducting conductor shield. Copper is used for this application because of its amazing electrical properties and flexibility.
Shield:
The shield prevents electromagnetic interference from affecting the cable; it also protects the cable from other external mechanical damages. The shield of this metal clad cable is made of uncoated copper tape. (min. 12.5% overlap).
Insulation:
Insulation is very important in any electrical cable since it prevents the electrocution of cable handlers. This metal cable insulation is made of ethylene-propylene rubber (EPR), which is in line with ICEA S-96-659. This material is strong and resistant to harsh environmental conditions.
Armor:
The armor protects the cable from external damages in addition to the shield and is made using impervious continuously welded and corrugated aluminum.
Jacket:
This metal clad cable jacket is made of PVC. This material is resistant to flames, sunlight, chemicals, abrasion, corrosion, moisture, industrial solvents, oils, acids, alkalis, and radiation.
Specifications:
- Size (AWG/kcmil): 4
- Number of Conductors: 3
- Number of Strands: 7
- Insulation Thickness (mils): 115
- Ground Wire Size (AWG): 6
- Armor Overall Diameter (inches): 1.64
- Jacket Thickness (mils): 60
- Overall Diameter (inches): 1.76
- Net Weight (Lbs/Mft): 1450
Compatible with Manufacturer |
|
Houston Wire & Cable : | HW31000403 |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460