3500 MCM Copper SW Standard Wall Laminate Sheath 230 kV XLPE Power Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
3500 MCM Copper SW Standard Wall Laminate Sheath 230 kV XLPE Power Cable
Applications:
Predominantly used for underground transmission in conduit systems, suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 230,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation Segmental Cu smooth conductor shield, super clean XLPE insulation, true triple extrusion and dry cured, firmly bonded insulation shield, Cu moisture impervious sheath, PE jacket with extruded semi-conductive outer layer.
Also Known As:
3500 MCM 230 kV Copper Conductor XLPE Insulated Power Cable with Laminate Sheath Copper Wire Screen (SW) Standard Wall XLPE 230 kV Transmission Cable 230 kV High-Voltage XLPE Cable with Laminated Metallic Sheath Copper Conductor Laminate Sheathed XLPE Underground Power Cable 230 kV Extra 3500 MCM High Voltage (EHV) XLPE Power Cable – Copper SW Type Copper Screened XLPE Insulated 230 kV Power Transmission Cable Standard Wall 3500 MCM XLPE Laminate Sheath Copper EHV Cable 230 kV Copper XLPE Insulated Laminated Sheath Underground Cable High-Voltage Copper SW XLPE Laminate Sheath Cable 230 kV Copper Conductor Laminated Sheath Power Transmission Cable
Cable Construction:
• Concentric Stranded, Compact, or Segmental Copper Conductor
• Smooth Conductor Shield
• Super Clean XLPE Insulation
• True Triple Extrusion and Dry Cured
• Firmly Bonded Insulation Shield
• Copper Moisture Impervious Sheath
• Polyethylene Jacket with Extruded Semi-Conductive Outer Layer
CABLE DATA:
Voltage Characteristics (kV)
Max Voltage Rating: 245
BIL Rating: 1050
Temperatures (°C)
Nominal Conductor: 90
Max. Emergency Conductor: 105
Short Circuit Conductor: 250
Minimum Installation: -10
Design Characteristics
Design Standards: AEIC, IEC
Factory Test Voltages (@400 kV): 265 kV / 60 min
XLPE Loss Factor: 0.0005
Relative Permittivity: 2.3
Specifications:
Conductor Size: 3500 MCM
Conductor Dia. (inches): 2.07
Insulation Thickness (mils): 906
Diameter Over Insulation (inches): 4.07
Overall Jacket Diameter (inches): 4.81
Min. Bending Radius (install / perm.) (inches): 87/58
Capacitance (pF/ft): 69.00
Charging Current (A/kft): 3.45
Cable Weight (lbs/ft): 7.35
Ampacity @ 90°C; Single Circuit (Fig 1): 1690 Amps
Power Rating: ó73 MVA
Ampacity @ 90°C; Double Circuit (Fig 2): 1390 Amps
Power Rating: 554 MVA
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460