350 AWG 893 Strand Bare Copper XLPE RW90 Machine Flex Power Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
350 AWG 893 Strand Bare Copper XLPE RW90 Machine Flex Power Wire
Applications:
Type XHHW-2 & RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 & RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.
Also Known As:
350 AWG Copper RW90 Machine Flex Cable XLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 350 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 350 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 / RW90 Machine Flex Power Wire (where dual-rated) 600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
• UL 44 Thermoset-Insulated Wires and Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
• CSA C22.2 No. 38 Thermoset-insulated wires and cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in
the RoHS-2 (2011/65/EU) Directive
• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)
and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
• Sunlight Resistance
Construction:
1. Conductors: 8 AWG - 4/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper
2. Insulation: Black, sunlight, gas, & oil resistant Cross-Linked Polyethylene (XLPE)
Specifications:
• Size: 350 AWG
• Cond. Number: 1
• Number of Strands: 893
• Diameter Over Conductor inch : 0.670
• Insul Thickness (mil): 65
• Approx. OD (inch) : 0.810
• Approx. Weight lb/1000ft : 1179
• DC Resistance @ 25°C: 0.033
• AC Resistance @ 90°C : 0.042
• Inductive Reactance@ Ω/1000ft : 0.040
• Max Pull Tension lb: 2800
• Min Bending Radius lb: 3.2
• Allowable Ampacity At 75°C Amp : 310
• Allowable Ampacity At 90°C Amp : 350
|
Compatible with Manufacturer |
|
| Southwire | 457087 |
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460