3 x 2.5 mm² TRDFC-SC Single Sheath Collective Screen 0.6/1KV Flexible Power And Control Round Festoon Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
3 x 2.5 mm² TRDFC-SC Single Sheath Collective Screen 0.6/1KV Flexible Power And Control Round Festoon Cable
Allowable Ampacity for 3 x 2.5 mm² TRDFC-SC Single Sheath Collective Screen 0.6/1KV Flexible Power And Control Round Festoon Cable : 100 Amps
Description :
- Flexible power and control cable
- For use on festoon systems
- RMGC, RTGC, GC, OHC etc.
Also Known As :
TRDFC-SC Cable, Flexible Cable, Control Cable, Power Cable, Flame Retardant Cable, Tinned Copper Cable, Festoon Cable, Marine Cable
Construction :
- Flexible tinned copper
- IEC 60228 Class 5
Insulation :
- EPR, Better than IEC 60502-1
Collective Screen :
- Braid screen made of tinned copper wires and polyester yarn
Sheath :
- SE1, Better than IEC 60502-1, Black
Cores Identification :
- If without earth conductor, White with black numbering
- If with earth conductor, White with black numbering + green (or green / yellow)
Marking :
- If without earth conductor, TRDFC-SC 0.6/1kV Number of cores x cross-section TMC Year Length
- If with earth conductor, TRDFC-SC 0.6/1kV Number of cores G cross-section TMC Year Length
Electrical Properties :
- Rated Voltage(Uo/U) : 0.6/1kV
- AC Test Voltage : 3.5kV/5min.
- Current Rating(A) : IEC 60364-5-52
Mechanical Properties :
- Tensile Stress Max: 15N/mm2
- Bending Radius
- 20mm ≥ D : Min. 6 x D
- 20mm < D : Min. 8 x D (D : Cable diameter)
- Torsion Stress : Not Permitted
- Traveling Speed : Max. 210m/min
- Additional Tests : Bending
Thermal Properties :
- Maximum Conductor Temperature
- Normal Operation : 90℃
- Short-Circuit(5s) : 250℃
- Ambient Temperature
- Moved : 25℃ to +60℃
- Not Moved : 40℃ to+80℃
Chemical Properties :
- Oil Resistance : IEC 60811-2-1
- Flame Retardant : IEC 60332-1
- Weather Resistance : Ozone, UV
Specification :
- Number of Core : 3 x 2.5 mm2
- Diameter (Approx) : 2.0 mm
- Resistance (At 20℃) : 8.210 Ω/km
- Overall Diameter Min. : 14.1 mm
- Overall Diameter Max. : 16.6 mm
- Weight : 300 kg/km
- Tension Stress Max. : 112 N