3/0-3 5/3 Stranded Bare Copper Tape XLPE PVC Gaalflex Tray VFD 1420 2000V Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
3/0-3 5/3 Stranded Bare Copper Tape XLPE PVC Gaalflex Tray VFD 1420 2000V CableAllowable Ampacity for 3/0-3 5/3 Stranded Bare Copper Tape XLPE PVC Gaalflex Tray VFD 1420 2000V Cable: 100 Amps
About:
This cable likely refers to a type of variable frequency drive (VFD) cable used in industrial and automation settings. The numbers "3/0-3" and "5/3" may refer to the American Wire Gauge (AWG) sizes of the conductors. The "1420 2000V" might indicate the voltage rating.
Also Known As:
It might be known under different names depending on the manufacturer or specific use. For instance, it could be referred to as VFD cable, industrial power cable, or automation cable.
Application:
Such cables are typically used in environments where variable frequency drives are used to control motors, like in manufacturing plants, HVAC systems, or conveyor systems. They are designed to handle the power requirements and electromagnetic interference associated with VFD systems.
Standards:
• UL 44 2000 V thermoplastic insulation
• UL 1277 60°C for Oil Res I
• CSA C22.2 No 230 for tray cable
• CSA C22.2 No 239 for control and instrumentation cable
Construction:
• Conductor: finely stranded red copper, acc.to ASTM B-3 and ASTM B-174
• Insulation: special XLPE compound
• Colour cores: acc. to ICEA S-58 679 method 4 black conductors whit number printed
• Earth conductor: Finely stranded red copper acc.to ASTM B-3 or ASTM B-174
• Earth conductor insulation: Uninsulated
• Stranding: In layers
• Screen: Red copper tape
• Outer Sheath: Black (similar RAL 9005), special PVC compound
Features:
• UV resistant
• Outdoor use
• Installation in hazardous areas
• UL 1277 type TC-ER 2000 V, 90°C Dry 90°C Wet
• WTTC 90°C DRY 1000 V
• UL: type RHH or RHW-2 conductors per UL 44 and ICEA S-95-658, NEMA WC 70
• On request UL type TC-ER 600 V 90°C Dry 90°C Wet
• CSA: c (UL) CIC/TC FT4
• Suitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3
• RoHS approval
• EPA 40 CFR, part 261
• OSHA and MSHA on request
• On request special EPR compound insulation version
• Tinned copper on request
Specifications:
• No. of cores x cross section n x AWG/MCM: 3 x 3/0 + 3 G 5
• Outer-Ø ca.mm ± 10%: 40,39
• Copper weight: 2991 kg/km
• Nominal voltage UL: 2000 V
• Temperature range UL: Fixed laying: - 25°C up to + 90°C, Flexible installation: - 25°C up to + 90°C
• Min. bending radius: 12 x d
• Cable Weight approx Lbs/Mft: 2619
• Part Number: 33120171037A3C
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460