26 AWG 18P Helukabel 21014 PAAR-TRONIC-CY PVC Data Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
26 AWG 18P Helukabel 21014 PAAR-TRONIC-CY PVC Data Cable
Applications:
Suitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as control and signal cables for systems at risk of interference radiation. Due to the dense braided screening, interference through parallel running cables is suppressed and as a result of the pair stranding, favourable crosstalk attenuation values are achieved. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Also Known As:
26 AWG 18P Helukabel Paar Tronic CY cable, Paar Tronic CY PVC data cable, Helukabel shielded data cable, CY screened control cable, Helukabel PVC screened cable, Helukabel data transmission cable, Paired shielded data cable, 26 AWG 18P Helukabel CY instrumentation cable, Helukabel EMC data cable, 26 AWG 18P Helukabel PVC flexible data cable.
Technical Data:
PVC data cable in alignment with DIN VDE 0812
Temperature range
flexible -5°C to +80°C
fixed -30°C to +80°C
Peak operating voltage
350 V (not for high power current installation purposes)
Test voltage core/core
1200 V
Test voltage core/screen
800 V
Breakdown voltage
2400 V
Mutual capacitance core/core
at 800 Hz 0.14 - 0.25 mm²: approx. 100 pF/m 0.34 - 1.5 mm²: approx. 150 pF/m
Mutual capacitance core/screen
at 800 Hz 0.14 mm²: approx. 240 pF/m 0.25 mm²: approx. 270 pF/m
Capacitive coupling k1
at 800 Hz, max. 300 pF/100m
Characteristic impedance
78 Ohm, (approx. value)
Inductance
approx. 0.65 mH/km
Coupling resistance
at 30 MHz, approx. 250 Ohm/ km
Minimum bending radius
flexible 10x Outer-Ø
fixed 5x Outer-Ø
Cable Structure:
• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Wire structure:
0.14 mm²: approx. 18 x 0.1 mm
0.25 mm²: approx. 14 x 0.15 mm
0.34 mm²: 7 x 0.25 mm
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
• Core identification acc. to DIN 47100 (paired stranding), colour coded
• x = without protective conductor
• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths
• Foil wrapping
• Drain wire, tinned copper
• Screen: braided screen of tinned copper wires, approx. coverage 85%
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: grey (RAL 7032)
• Length marking: in meters
Properties:
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests:
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• certifications and approvals: EAC
Notes:
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Specification:
• Size : 26 AWG
• No. cores x cross-sec.mm²: 18 x 2 x 0.14
• Outer Ø. mm approx: 10.9
• Cu factor per km: 83.0
• Weight approx kg/km: 171.0
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460