2500 MCM Copper SW Standard Wall Corrugated Sheath 345/400 kV XLPE Pow
nassaunationalcable.com/products/2500-mcm-copper-sw-standard-wall-corrugated-sheath-345-400-kv-xlpe-power-cable
Items in Cart ()
View cart

2500 MCM Copper SW Standard Wall Corrugated Sheath 345/400 kV XLPE Power Cable

2500 MCM Copper SW Standard Wall Corrugated Sheath 345/400 kV XLPE Power Cable
Roll over image to Zoom
2500 MCM Copper SW Standard Wall Corrugated Sheath 345/400 kV XLPE Power Cable
SKU: NNCSW2500
copper-sw-standard-wall-xlpe-corrugated-sheath-345-400-kv-xlpe-power-cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

2500 MCM Copper SW Standard Wall Corrugated Sheath 345/400 kV XLPE Power Cable

Applications:

Predominantly used for underground transmission in conduit systems, suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 345,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.

Also Known As:

2500 MCM Copper SW XLPE power cable, 2500 MCM 345/400 kV XLPE cable, Corrugated sheath power cable, High voltage XLPE cable, Copper power cable XLPE, 345 kV power cable, XLPE insulated power cable, Corrugated sheath cable 345 kV, XLPE cable for high voltage, 400 kV copper XLPE cable.

Cable Construction:

Conductor: Concentric Stranded, Compact, or Segmental Copper Conductor
Conductor Shield: Smooth
Insulation: Super Clean XLPE Insulation with a true triple extrusion and dry curing process.
Shielding: Firmly Bonded Insulation Shield
Outer Sheath: Polyethylene jacket with an extruded semi-conductive outer layer.
Moisture Protection: Copper moisture-impervious sheath.

CABLE DATA:

Voltage Characteristics (kV)

Max Voltage Rating: 420
BIL Rating: 1300/1425

Temperatures (°C)

Nominal Conductor: 90
Max. Emergency Conductor: 105
Short Circuit Conductor: 250
Minimum Installation: -10

Design Characteristics

Design Standards: AEIC, IEC
Factory Test Voltages (@400 kV): 440 kV / 60 min.
XLPE Loss Factor: 0.0005
Relative Permittivity: 2.3

Standards & References:

• ICEA S-108-720 AEIC CS9 - And IEC 60840 or 62067 upon request as applicable

Specifications:

Conductor Size: 2500 MCM
Conductor Dia. (inches): 1.73
Insulation Thickness (mils):  1063
Diameter Over Insulation (inches):   4.05
Overall Jacket Diameter  (inches):   5.23
Min. Bending Radius (install / perm.) (inches):  95/63
Capacitance (pF/ft):   54.58
Charging Current (A/kft):  4.75
Cable Weight (lbs/ft):   15.78
30 mil Sheath2 Short Ckt @ 0.5s (kA):  60.3
Ampacity @ 90°C; Single Circuit (Fig 1):  1310 Amps
Power Rating:   908 MVA
Ampacity @ 90°C; Double Circuit (Fig 2): 1070 Amps
Power Rating: 741 MVA


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460

Win an Exclusive prize!

Enter your full name and email to spin the wheel for a chance to win