250 MCM 3C HVTECK Copper 115 mil TRXLPE TS AIA 5kV 133% or 8kV 100% IL Orange PVC Jacket CSA

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
250 MCM 3C HVTECK Copper 115 mil TRXLPE TS AIA 5kV 133% or 8kV 100% IL Orange PVC Jacket CSA
Application:
The 5kV / 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. For installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports and concrete encase able. Rated for 1000 lbs / FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant 3 Conductor, 115 Mils Tree Retardant Cross Linked Polyethylene, 5kV 133% or 8kV 100% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket
Also known as:
Construction:
Conductor:
Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Conductor Shield:
Semi-conducting cross-linked copolymer
Insulation:
115 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
Insulation Shield:
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Filler:
Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor:
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder:
Polypropylene tape
Inner Jacket:
PVC inner jacket
Armour:
Aluminum Interlocked Armour (AIA)
Overall Jacket:
Orange Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
Specification:
• Size: 250 MCM
•Number of conductor: 3
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.558
• Diameter Over Insulation (inch): 0.818
• Insul. Thickness mil: 115
• Diameter Over Insulation Shield (inch): 0.878
• Ground Size AWG: 4
• Inner Jacket Thickness (mil): 110
• Diameter Over Armor (inch): 2.510
• Overall Jacket Thickness mil : 75
• Approx. OD inch : 2.660
• Copper Weight lb/1000ft: 2689
• Approx. Weight (Lbs/1000'Ft): 4697
• DC Resistance @ 25°C Ω /1000ft: 0.043
• AC Resistance @ 90°Ω /1000ft: 0.056
• Allowable Ampacity In Air 90°C Amp: 376
• Allowable Ampacity Directly Buried 90°C Amp: 410
[short]