20 AWG 4C HELUKABEL 16202 Y-CY-JZ PVC Control and Connection Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
20 AWG 4C HELUKABEL 16202 Y-CY-JZ PVC Control and Connection Cable
Applications:
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry rooms, however, not suitable for outdoor use. Used as a connection and control cable in measurement and control technology, in machine and machine tool construction, in conveyers and Due to production lines, in computers, as well as signal cables in electronics. the high screening density, interference free transmission of signals or pulses is ensured. The PVC inner sheath increases the mechanical load capacity of the cable the transparent PVC outer sheath makes the tinned copper braid optically effective.EMC = Electromagnetic Compatibility: in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Also Known As:
20 AWG 4C HELUKABEL Y-CY-JZ / Y-CY-JZ Shielded Control Cable HELUKABEL PVC Shielded Control and Connection Cable 20 AWG 4C HELUKABEL JZ Shielded PVC Cable Y-CY-JZ PVC Shielded Cable Y-CY-JZ PVC Connection and Control Cable PVC Shielded Y-CY Control Cable 20 AWG 4C HELUKABEL JZ / Y-CY-JZ PVC Cables Y-CY Shielded PVC Control Cable PVC Control and Connection Y-CY-JZ Cable
Technical Data:
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
Temperature range
flexible -15°C to +80°C
fixed -40°C to +80°C
Nominal voltage
AC U0/U 300/500 V
Test voltage core/core
4000 V
Breakdown voltage
8000 V
Mutual capacitance core/core
at 800 Hz
0.5 - 2.5 mm²: approx.150
pF/m
Mutual capacitance core/screen
at 800 Hz
0.5 - 2.5 mm²: approx. 270
pF/m
Coupling resistance
at 30 MHz, approx. 250 Ohm/km
Minimum bending radius
flexible 10x Outer-Ø
fixed 5x Outer-Ø
Cable Structure:
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC, compound type Z 7225
• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
• Protective conductor: starting with 3 cores,
G = with protective conductor GN-YE, in the outer layer,
x = without protective conductor (OZ)
• Cores stranded in layers with optimal lay lengths
• Inner sheath: PVC
• Screen: braided screen of tinned copper wires, approx. coverage 85%
• Outer sheath: PVC
Properties:
• Largely resistant to: oil, for details, see "Technical Information"
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquer
Tests:
• Flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• Certifications and approvals: VDE-Reg.-No. 7032, valid for temperature range up to +70°C
Notes:
• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
• Sheath colour: transparent
• Length marking: in metres
Specifications:
• Size : 20 AWG
• No. cores x cross-sec. mm²: 4 G 0.5
• Outer-Ø min - max mm: 7.9
• Cu factor per km: 54.0
• Weight kg/km, approx: 94.0