2-2-2-2 Wittenberg Quadruplex Aluminum Conductor Underground Direct Burial 600V URD

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
2-2-2-2 Wittenberg Quadruplex Aluminum Conductor Underground Direct Burial 600V URD
Allowable Ampacity for 2-2-2-2 Wittenberg Quadruplex Aluminum Conductor 600V URD direct burial: 155 Amps
Allowable Ampacity for 2-2-2-2 Wittenberg Quadruplex Aluminum Conductor 600V URD in duct: 115 Amps
Applications:
The 2-2-2-2 Wittenberg Quadruplex Aluminum URD Cable is designed for low-load secondary distribution in underground electrical systems. It is 600V-rated and suitable for direct burial or installation in ducts. With aluminum conductors and XLPE insulation, this cable is moisture-resistant, heat-resistant, and durable for outdoor use.
With a maximum operating temperature of 90°C, it performs reliably in both wet and dry environments. Its quadruplex configuration ensures balanced power distribution, making it ideal for utility and residential applications.
Also Known As:
2-2-2-2 wittenburg aluminum urd cable, 2-2-2-2 wittenburg urd direct burial cable, 2-2-2-2 wittenburg quadruplex cable, 2-2-2-2 wittenburg quadruplex wire, 2-2-2-2 wittenburg four conductor wire, 2-2-2-2 wittenburg four conductor cable, 2-2-2-2 wittenburg direct burial electrical cable, 2-2-2-2 wittenburg direct burial power cable, 2-2-2-2 wittenburg aluminum direct burial cable.
Specific Use Cases of 2-2-2-2 URD
This cable supports low-load three-phase secondary distribution, delivering 2 AWG conductors with a matching neutral for residential, utility, and light commercial use.
- It powers service meters in small residential subdivisions and rural distribution networks.
- It supplies underground power to light commercial buildings and municipal facilities.
- It provides electricity to single-family homes and small multi-unit residences.
- It is used in underground vaults and secondary power panels.
- It connects small-scale renewable energy systems to the grid.
- It supports temporary power setups for construction sites and backup systems.
Standards:
-
ASTM B-230
-
ASTM B-231
-
ASTM B-609
-
ASTM B-901
-
ICEA S-105-692
-
Federal Specification J-C – 30B
-
RUS ACCEPTED
Construction
Conductors:
Aluminum conductor used for this cable is either a concentric strand or compressed 1350-H19 series aluminum conductor. The conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe.
Insulation:
Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.
Specifications:
-
Size AWG: 2
-
Stranding: 7
-
Insulation Thickness (mils): 60
-
Neutral Size AWG: 2
-
Single Phase Conductor Inches: 0.403
-
O.D. Inches: 0.973
-
Weight lbs./1000ft: 375 lbs
-
Ampacity: Direct burial: 155 Amps
-
Ampacity: In duct: 115 Amps