2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtigh
nassaunationalcable.com/products/2-trade-electri-flexible-conduits-galvanized-steel-type-la-liquidtight-jacket-pvc

Items in Cart ()

View cart

2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC
Roll over image to Zoom

2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

SKU: 26804
electri-flexible-conduits-galvanized-steel-type-la-liquidtight-jacket-pvc
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

US Trade Size: 2"
ISO: 63 (mm)
CSA: 53 (mm)
Type: LA-16
Internal Diameter: Min: 2.020 Inches & Max: 2.045 Inches
Outer Diameter: Min: 2.340 Inches & Max: 2.375 Inches
Inside Bend Radius: Static: 6.0 Inches & Dynamic: 22.0 Inches
Weight: 152.25 Lbs
Reel 50ft: Part Gray: 26102 & Part Black: 26802
Reel 100ft: Part Gray: 26104 & Part Black: 26804


2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC

Allowable Ampacity for 2" Trade Electri Flexible Conduits Galvanized Steel Type LA Liquidtight Jacket PVC: 100 Amps

Application:

This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI/NFPA-70) and in section 14.5.4 of the ANSI/NFPA-79 Standard for Industrial Machinery:

  • Listed and marked for Direct Burial and in Poured Concrete
  • For containment of 1000 volt and lower potential circuits
  • Suitable as a grounding conductor when used for circuits rated up to 20A for the 3/8 & 1/2 inch trade sizes and 60A for the 3/4 through 1-1/4 inch trade sizes in lengths six feet or less per NEC Article 250.118(6). Larger sizes require separate grounding conductor.
  • Installations in hazardous (classified) locations:
  • Class I Div. 2: Article 501.10 (B)(2) & 501.30 (B)
  • Class II Div. 1: Article 502.10 (A)(2) & 502.30 (B) Div. 2: 502.10 (B)(2)
  • Class III Div. 1: Article 503.10 (A)(3) & 503.30 (B) Div. 2: 503.10 (B)
  • Installed under raised floors in Data Processing Areas Articles 645.5 (E)
  • Electric Signs and Outline Lighting over 1000 volts Articles 600.7/600.32(A)(1)
  • Permitted for Service Entrance wiring to six feet Article 230.43
  • Used as Feeders and Services at Marinas and Boatyards Article 553.7(B)
  • Wiring on Building Article 225.10
  • Conductor Enclosures Adjacent to Motors over 1000 V Article 430.223
  • Underground Service, Feeder, Branch Circuit, and Recreational Vehicle Site Feeder Circuit Conductors Article 551.80
  • Elevators and Hoistways Article 620.21
  • Pools and Fountains Article 680
  • Bodies of water. Article 682
  • Fire Pumps. Article 695

This conduit is intended for use according to the Canadian Electrical Code (CEC CSA 22.1-18) as described in clause 12-1300 for dry, damp or wet locations.

  • Conforms to CSA C22.2 No. 56-17 Annex A “Heavy Duty”

Hazardous Locations areas where flexibility is necessary:

  • Class I Div 2: CSA 22.1 J18-152 (1) (i)
  • Class II Div 1: CSA 22.1 J18-204 (4) (b)
  • Class II Div 2: CSA 22.1 J18-254 (1) (h)
  • Class III Div 1: CSA 22.1 J18-304 (1) (f)
  • Class III Div 2: CSA 22.1 J18-354 (h)
  • Zone 2: CSA 22.1 18-152 (1) (h)
  • Zone 20: CSA 22.1 18-192 (3) (a)
  • Zone 21: CSA 22.1 18-202 (4) (a)
  • Zone 22: CSA 22.1 18-252 (1) (h)


Also Know As:

Electri Flexible Conduits, Flexible Conduits, Galvanized Steel, Liquidtight Jacket, Type LA Conduits, Jacketed Metallic, Flexible PVC, Flexible Steel Conduit, Heavy-Duty

Type LA

A exible steel conduitwhich is both listed by Underwriters Laboratories Inc. and certied by Canadian Standards Association for“Heavy-Duty” applications. It oers outstanding protection againstwet, oily conditions and is permitted for use in exposed or concealed locations.

Construction:

Inner Core:

  • Hot Dipped Galvanized Steel
  • 3/8” – 1-1/4” Squarelock Profile with continuous bonding strip
  • 1-1/2” – 4” Fully Interlocked Profile

Liquidtight Jacket:

  • Flexible PVC
  • Resistant to Oils and Mild Acids
  • Flame Retardant
  • Sunlight Resistant (UV)
  • Marked HD for “Heavy-Duty”

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color