2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral TR-XLPE / LLDPE MV-90 133% 90 mil 5 kV

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral TR-XLPE / LLDPE MV-90 133% 90 mil 5 kV
Application:
• Underground primary residential and commercial distribution circuits.
• May be used in wet or dry locations, installed in underground ducts or direct burial.
Also Known As:
2 AWG Aluminum TR-XLPE UD cable, LLDPE Concentric neutral cable, 5kV-46kV underground primary cable, 2 AWG TR-XLPE insulated power cable, 2 AWG Concentric neutral primary cable, XLPE LLDPE power cable.
Standards:
• ICEA S-94-649: Standard for Concentric Neutral Rated Cables 5 – 46 kV.
• AEIC CS8: Specifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.
Construction:
• Conductor: Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8 or hard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request: larger sizes.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE). On request: super-clean and super-smooth materials.
• Insulation: Thermoset tree-retardant crosslinked polyethylene (TR-XLPE).
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Concentric Neutral: Soft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.
• Jacket: Extruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.
Features:
• Low tension stripping compounds.
• RUS U-1 (15 kV & 25 kV).
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.
• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.
• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.
• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.
• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.
• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.
Specifications:
• Size: 2 AWG
• Full Neutral Size: 14 AWG
• Number of Strands: 7
• Number of Wires: 10
• Jacket Thickness (mil): 50
• Approximate Outside Diameter (In): 0.81
• Aluminum Rating Voltage: 5 kV
• Approximate Net Weight lb/kft: 374
*Data provided on this page is subject to change based on different manufacturers' variances