Applications:
UL/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Also Known As:
18 AWG 41C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 41C Copper Shielded Cable UL/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal & Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 41C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable
Technical Data:
PVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I/II A/B
Temperature range
flexible -10°C to +90°C
fixed -40°C to +90°C
Nominal voltage
UL (AWM) AC 600 V
Test voltage core/core
3000 V
Breakdown voltage
6000 V
Coupling resistance
at 30 MHz, approx. 250 Ohm/km
Minimum bending radius
flexible 10x Outer-Ø
fixed 5x Outer-Ø
Cable Structure:
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210
• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
• Protective conductor: starting with 3 cores,
G = with protective conductor GN-YE, in the outer layer,
x = without protective conductor (OZ)
• Cores stranded in layers with optimal lay lengths
• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210
• Screen: braided screen of tinned copper wires, approx. coverage 85%
• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210
Properties:
• Largely resistant to: oil
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests:
• Flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2, UL VW-1, CSA FT1
Notes:
• The conductor is metrically (mm²) constructed, AWG numbers are
approximated, and are for reference only
• Sheath colour: grey (RAL 7001)
• Length marking: in metres
Specifications:
• Size : 18 AWG
• No. cores x cross-sec. mm²: 41 G 1
• Outer-Ø min - max mm: 22.0
• Cu factor per km: 531.0
• Weight kg/km, approx: 892.0
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460