160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concen
nassaunationalcable.com/products/160-23-4096-750-mcm-1c-61strand-aluminum-shield-1-3-neutral-epr-concentric-bc-pe-okoguard-uro-j-25kv-urd-cable

Items in Cart ()

View cart

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Roll over image to Zoom

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

SKU: 160-23-4096
okoguard-strand-aluminum-shield-neutral-epr-concentric-bc-pe-uro-j-25kv-urd-cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Allowable Ampacity for 160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable:100 Amps

About:

The single-conductor underground residential distribution (URD) cable, designed for primary distribution systems operating at 25kV. This cable features a stranded aluminum conductor, an aluminum shield, and a full concentric neutral. It is insulated with Ethylene Propylene Rubber (EPR) and protected with a Polyethylene (PE) jacket, making it suitable for direct burial or duct installations.

Also Known As:

 Okoguard URD Cable
 25KV URD Okoguard Cable
 Okoguard EPR 25KV Cable

Application:

• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits.

Standards:

 ICEA S-94-649: Standard for concentric neutral cables rated 5 through 46 kV
 AEIC CS8: Specification for extruded dielectric shielded power cables rated 5 through 46 kV
 UL 1072: Standard for medium-voltage power cables
 IEEE 1202/FT4: Standard for flame propagation testing of wire & cable
 NESC: National Electrical Safety Code

Construction:

• Central Conductor: Aluminum per ASTM B609, Class B stranded per B-231.
 Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: Bare copper wires.
• Jacket: Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system.
 Okoguard cables meet or exceed ICEA standards.
 Meets RUS 1728.204 for cables with filled strand or solid conductor and 100% insulation level.
 105°C continuous operating temperature.
 140°C emergency rating.
 250°C short circuit rating.
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to "treeing".
 Moisture resistant.
 Overall jacket provides extended life.
 Red extruded stripes.
 Excellent resistance to most chemicals.
 Can be listed by UL as Type MV-90 on Special Orders.
 CSAC68.5 listed, LTGG (-40°C), SR.
 Design Options:
 Additional conductor sizes
 Filled strand
• Copper central conductor
• Copper flat strap concentric neutral
 Product identification via colored jackets
 Semiconducting jackets
 Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 Minimum installation temperature of -40°C.

Specifications:

• Conductor Size AWG/kcmil: 750(61X)
• Nominal Dia. Over Insulation (in): 1.57
 Insulation Screen Thickness (miles): 40
• Nominal Dia. Over Insulation Screen (in): 1.67
• Copper Neutral No. x AWG(1): 16X.0966
• Nominal O.D (in): 2.03
• Approx. Net Weight: 2396
• 90°C Ampacity Direct Burial (2): 545 
• 90°C Ampacity Duct (2): 460
• 105°C Ampacity Direct Burial (2): 595 
• 105°C Ampacity Duct (2): 505
• Part Number: 160-23-4096


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460