140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutr
nassaunationalcable.com/products/140-23-4197-750-mcm-1c-bare-copper-unshielded-epr-concentric-1-3-neutral-okolene-25kv-260-okoguard-uro-j-cable

Items in Cart ()

View cart

140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable

140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable
Roll over image to Zoom

140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable

SKU: 140-23-4197
okoguard-bare-copper-unshielded-epr-concentric-neutral-okolene-uro-j-cable

Select a Gauge

140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable

Allowable Ampacity for 140-23-4197 750 MCM 1C Bare Copper Unshielded EPR Concentric 1/3 Neutral Okolene 25KV 260 Okoguard URO-J Cable:100 Amps

About:

This cable is constructed with a single conductor of 750 MCM bare copper, which is unshielded and insulated with Ethylene Propylene Rubber (EPR). The "concentric full neutral" design means that neutral wires completely encircle the insulated conductor, enhancing the cable's electrical balance and fault performance. The Okolene layer, designated here as "15KV 175," likely refers to its high voltage rating and thickness. The Okoguard URO-J is an outer jacket made from a unique compound designed for enhanced durability and protection against environmental factors.

Also Known As:

750 MCM Okoguard Cable
15KV Unshielded EPR Cable
Concentric Neutral Power Cable
Bare Copper Okolene Cable

Application:

 Okoguard URO-J cables provide maximum  circuit longevity in underground residential distribution systems. They can be buried direct or installed in underground ducts or conduits.

Standards:

• IEEE 1202/383 (UL 1685): For flame and fire resistance.
• ANSI/NEMA WC 70:
Concerning power cables rated up to 2000 volts.
• AEIC CS8-07:
Specifics for extruded dielectric shielded power cables.

Construction:

• Central Conductor: Uncoated soft copper. Compressed round conductors per ASTM
B-3 and ASTM B-8. Compact round conductors per ASTM B-496.
• Conductor Screen: 
Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation: 
Extruded Okoguard meets or ® exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation Screen: 
Two insulation screen thicknesses are available:
Cables with Compressed Round Copper Copper conductors have extruded
semiconducting ethylene-propylene rubber insulation screens that meet the
requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.Cables with Compact Round Copper conductors have extruded semiconducting ethylene-propylene rubber insulation screens that meet the requirements of ICEA S-93-639/NEMA WC74 & S-97-682, and AEIC CS8. 
• Concentric Conductor: 
Bare copper wires.
• Jacket: 
Black Okolene with red extruded ®stripes meets or exceeds the requirements
of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system
• Okoguard cables meet or exceed ICEA standards.
• 105°C continuous operating temperatures
• 140°C emergency rating
• 250°C short circuit rating
• Excellent corona resistance.
• Low dielectric constant and power factor.
• Screens are clean stripping.
• Exceptional resistance to "treeing".
• Moisture resistant.
• Excellent resistance to most chemicals.
• Can be listed by UL as Type MV-90 on Special Orders.
• CSA C68.5 listed, LTGG (-40°C), SR.
• Design Options:
- Additional conductor sizes
- Filled strand
- Copper flat strap concentric neutral
- Product identification via colored jackets.
- Semiconducting jacket.
• Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
These cables can be supplied with the following jackets for an MV-105 rating:
• FR-PVC Jacket, MV-105.
• XLPE Jacket, MV-105.

Specifications:

• Conductor Size AWG kcmil: 750(61x)
• Nominal Dia. over Insulation (in.): 1.50
• Insulation Screen Thickness (mils): 40
• Nominal Dia. over Screen (in): 1.60
• Copper Neutral No. x AWG (1): 24x.1010

• Nominal OD (in.): 1.97

• Approx. Net Weight (lbs): 4128
90ºC Ampacity Direct Burial (2): 650

• 90ºC Ampacitiy  Duct (2): 545
• 105ºC Ampacity Direct Burial (2): 710
• 105ºC Ampacity Duct (2): 600

• Part Number: 140-23-4197


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460