14 AWG 2C Unshielded Tray Cable XHHW-2 EPR Insulation CPE Jacket 600V E2
Applications:
Primarily used for power, control, signal, communication and lighting circuits in commercial and industrial environments. Suitable for installation in cable trays, supported by messenger in open air, raceways, channels, conduits and ducts. Approved for direct burial applications and outdoors in cable tray where sunlight resistant rating is required. Also may be installed in wet or dry locations or in areas exposed to chemicals and oils.
Also Known As:
14/2 Cable Tray, 14/2 Cable Tray Types, 14/2 Electrical Cable Tray, 14/2 Pvc Cable Tray, 14/2 wire cable tray, 14/2 cable tray wire, 14/2 TC-ER cable, 14/2 EPR Cable, 14/2 CPE Cable, 14/2 Tray Control Cable, 14/2 Tray Control Instrumentation Cable, 14/2 Multi-Conductor Tray Cable, 14/2 Exposed Run Tray Cable.
Standards:
• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors
• Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
• Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
• Rated at 90°C wet or dry
• Oil Res I & II
• “Heavy Duty” rating per ICEA Standards
• Meets cold bend test at -25°C
• NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
• IEEE 1202 and CSA FT4 70,000 BTU Flame Test
• IEEE 383 70,000 BTU Vertical Flame Test
• ICEA T-29-520 210,000 BTU
Conductor:
• Fully annealed tinned copper Class B compressed strand per ASTM B-33 and ASTM B-8
Insulation:
• Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44
Assembly:
• Conductors are cabled together with or without fillers as required to form a round, compact cable core with a binder tape
Jacket:
• Flame and sunlight resistant black thermoplastic Cross-linked Chlorinated Polyethylene (XL-CPE) rated 90°C wet or dry per UL 1277. Excellent flame resistance that allows the jacket to burn to an ash and does not exhibit the thermoplastic drip characteristic. Ripcord provided for jackets with thickness of 60 mils or less.
Options:
• ICEA Method 1, Table E-1 or E-2 Color Code
• Bare Copper
• Shielding
Specification:
• Gauge: 14 AWG
• No. Conductors: 2
• Stranding: 7
• Insulation Thickness: 0.030 Inches
• Jacket Thickness: 0.045 Inches
• Overall Diameter : 0.356 Inches
• New Weight lb/1000FT: 71 Lbs
Compatible with Manufacturer |
|
General Cable item : | 279560 |
Omni Cable item : | AF11402 |
Southwire item : | 591943 |
Houston Wire item : | HW15801402 |
Priority Wire & Cable : | 14-02TC-XLPCPE |
AWC : | EPR/CPE 14-2C |