14 AWG 2C Bare Copper Unshielded Halogen-Free FTG18(O)M16 0.6/1KV Security Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
14 AWG 2C Bare Copper Unshielded Halogen-Free FTG18(O)M16 0.6/1KV Security Cable
Allowable Ampacity for 14 AWG 2C Bare Copper Unshielded Halogen-Free FTG18(O)M16 0.6/1KV Security Cable: 100 Amps
About:
This cable features two conductors (2C) made of bare copper, renowned for its effective electrical conductivity. The designation "14 AWG" specifies the gauge or thickness of each conductor, which is an important factor in determining its current-carrying capacity and resistance. Being unshielded, it does not have additional layers for electromagnetic interference protection, which is typically not necessary for its intended low-frequency or direct current applications. The "halogen-free" aspect indicates that the materials used in the cable's construction do not contain halogens, reducing the emission of toxic gases and smoke in fire situations.
Also Known As:
• "14 AWG 2C security cable"
• "Halogen-free safety cable"
• It might also be identified through industry-specific nomenclature reflecting its construction and applications.
Application:
• Security and alarm systems, where it might be used for connecting sensors, cameras, or access control units.
• Emergency lighting or safety systems, ensuring operational integrity in case of fire.
• Buildings requiring cabling with reduced fire risk and toxic emissions, including hospitals, schools, airports, and commercial complexes.
Standards:
• IEC 60502-1, pertaining to the construction and performance of power cables.
• The halogen-free aspect aligns with standards aimed at limiting toxic emissions and smoke in case of fire, essential for enhancing occupant safety in enclosed spaces.
Construction:
• Conductor: Flexible red copper conductor Cl.5, acc.to IEC 60228
• Insulation: Mica tape + rubber type G18
• Filler: non-fibrous and non-higroscopic filler compound
• Outer Sheath: Blue (RAL 5015), halogen-free type M16
Features:
• According to IEC 60502-1
• IEC EN 60332-1-2, EN 50399
• According to CPR UE 305/11, EN 50575:2014 + A1:2016, B2ca-s1a, d1, a1
• Classification (CEI UNEL 35016), EN 13501-6
• CEI 20-45 V2
Specifications:
• No. of cores x cross section n x mm²: 2x2,5
• AWG no.: 14
• Outer-Ø ca.mm ± 10%: 13,5
• Copper Weight kg/km: 48
• Nominal Voltage: Uo/U 0,6/1 kV
• Test Voltage: 4 kV
• Temperature Range: Fixed laying: - 25° C up to + 90° C, Flexible application: 0° C up to + 90° C
• Max short circuit temperature: + 250 °C
• Min. bending radius: Control: 14 x D, Power: 12 x D
• Cable Weight approx. kg/km: 232
• Part Number: 49340GB3020M25
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460