Applications:
Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Also Known As:
12 AWG 12C Multi-Conductor Copper Control Cable, 12 AWG 12C 600V, FR-XLPE Insulation, CPE Jacket,12 AWG 12C Flame-Retardant XLPE CPE Jacketed Control Cable, 12 AWG 12C 600V,Thermoset Insulated Multi-Conductor Control Cable,12 AWG 12C 600V FR-XLPE/CPE Industrial Control Cable,12 AWG 12C Multi-Conductor XLPE Insulated CPE Jacket Cable, Copper Control Cable with FR-XLPE and CPE Jacket, 12 AWG 12C 600 Volt, 600V Thermoset XLPE/CPE Jacketed Copper Cable,12 AWG 12C Multi-Conductor 600V XLPE/CPE Copper Control Wire
Standards:
ASTM B3 Standard Specification for Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• UL 1277 Electrical Power and Control Tray Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
• VW-1 (Vertical-Wire) Flame Test
Construction:
Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8
Insulation:
Flame Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
Filler:
Polyester flat thread binder tape applied for cables with more than 5 conductors
Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductors
Rip Chord:
Rip chord for ease of jacket removal
Overall Jacket:
Thermoset Chlorinated Polyethylene (CPE) Jacket
Specifications:
• Size: 12 AWG
• Number of Conductors: 12
• Diameter Over Conductor (inch): 0.087
• Insulation Thickness (Mil): 30
• Jacket Thickness (Mil): 60
• Approx. OD (In): 0.732
• Copper Weight (Lbs/1000'Ft): 244
• Approx. Weight (Lbs/1000'Ft): 419
• Min Bending Radius (In):2.9
• Allowable Ampacity In Air 90°C (Amp): 15