1150 MCM 1C Stranded Bare Copper Tape Shield Armour Al PVC RE4H1RFR 6/10KV Medium Voltage Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
1150 MCM 1C Stranded Bare Copper Tape Shield Armour Al PVC RE4H1RFR 6/10KV Medium Voltage CableAllowable Ampacity for 1150 MCM 1C Stranded Bare Copper Tape Shield Armour Al PVC RE4H1RFR 6/10KV Medium Voltage Cable: 100 Amps
About:
This cable is engineered to transport electricity at medium voltage levels, specifically designed for 6 to 10 kilovolts. It features a single conductor (1C) made of 1150 MCM American Wire Gauge (AWG) stranded bare copper, enhancing both its conductivity and flexibility.
Also Known As:
This cable might have different nomenclatures based on its key attributes or manufacturer, emphasizing aspects like its 1150 MCM AWG size, stranded copper design, tape shielding, aluminum armor, and PVC jacketing.
Application:
• Infrastructure for power transmission in medium voltage ranges, such as in utility networks or industrial plants.
• Feeding power to transformers, switchgear, and other medium voltage equipment.
• Suitable for both outdoor and indoor environments, given its robust protective layers.
• Used in areas where mechanical protection and electromagnetic interference shielding are required.
Standards:
• IEC standards pertinent to medium voltage cables.
• ASTM standards for copper and aluminum quality.
• Possibly national or regional standards focusing on electrical systems and safety.
Construction:
• Conductor: Stranded Red Copper Conductor Cl.2, acc.to IEC 60228
• Inner Semi-Conductive Layer: Extruded Semi-Conducting Compound
• Insulation: XLPE compound
• Outer Semi-Conductive Layer: Extruded Semi-Conducting Compound
• Screen: Red Copper Tape
• Inner Sheath: PVC Compound
• Armour: Aluminium wires
• Outer Sheath: Red (RAL 3000), PVC type ST2
Features:
• According to IEC 60502-2
Specifications:
• No. of cores x cross section n x mm²: 1x630
• AWG no.: 1150 MCM
• Outer-Ø ca.mm ± 10%: 53
• Nominal Voltage: Uo/U 3,6/6 kV, Uo/U 6/10 kV, Uo/U 8,7/15 kV, Uo/U 12/20 kV, Uo/U 18/30 kV
• Test Voltage: Uo/U 3,6/6 kV = 11 kV, Uo/U 6/10 kV = 17 kV, Uo/U 8,7/15 kV = 24 kV, Uo/U 12/20 kV= 29 kV, Uo/U 18/30 kV = 45 kV
• Temperature range: - 0° C up to + 90° C
• Max short circuit temperature: + 250° C
• Min. Bending Radius: 14 x d
• Cable Weight approx. kg/km: 7950
• Part Number: 48110QRL010M75
*Data provided on this page is subject to change based on different manufacturers' variances