Items in Cart ()

View cart

115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable

115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable
Roll over image to Zoom

115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable

SKU: 115-23-3364

Select a Gauge

115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable

Allowable Ampacity for 115-23-3364 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 220mils 15KV Power Cable:100 Amps

About:

This power cable features a 2/0 AWG size, which is a large conductor size typically used for high-current applications. The "1C" denotes a single conductor, made from stranded, uncoated copper, providing good flexibility and conductivity. The "Okoguard" is the brand's proprietary insulation material, and "Okoclear-TP" refers to the transparent thermoplastic outer jacket. "MV-105" indicates that the cable is rated for medium voltage applications up to 15 kV. The "220mils" specifies the thickness of the insulation.

Also Known As:

This type of cable might not have a specific alternate name but could be described generically based on its construction and use, such as "15 kV single conductor medium voltage power cable."

Applications:

 Okoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke/zero halogen characteristics is needed.
 Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.
 May be installed in cable trays where permitted by NEC Section 392 as permitted by
NEC Section 315.32(3).

Standards:

While the specific standards are not mentioned, MV-105 designation suggests adherence to IEEE standards for medium voltage cables, ensuring performance under conditions like emergency overload, flame resistance, and environmental stress. Compliance with these standards ensures the cable is suitable for a wide range of medium voltage applications and environments.

Construction:

• Conductor: Uncoated copper compact stranded per ASTM B-496.
• Strand Screen:
 : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation:
 Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation Screen:
 Extruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Shield:
 5 mil bare copper tape helically applied, with 25% minimum overlap.
• Jacket:
 Meets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.
UL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.

Features:

 Low smoke/zero halogen jacket.
• 
Okoguard cables meet or exceed all recognized industry standards (UL,
NEMA/ICEA and IEEE).
• 
Triple tandem extruded, all EPR system.
• 
105°C continuous operating temperature.
• 
140°C emergency rating.
• 
250°C short circuit rating
• 
Excellent corona resistance.
• 
Exceptional resistance to “treeing”.
• 
Screens are clean stripping.
• 
Exceptional resistance to moisture.
• 
Resistant to most oils, acids, and alkalis.
• 
UL listed: MV-105, Sunlight Resistant, and Cable Tray Use.
• 
Passes the UL & IEEE 383-1974 Vertical Tray Flame Test.
• 
Sizes 500 kcmil and larger pass FT4/IEEE 1202 Vertical Tray Flame Test.

Specifications:

• Conductor Size AWG: 2/0
• Conduit Size Inches (5):
 3½
• Conductor Size mm²: 67.4
• Approx. Dia. over Insulation (in.): 0.86
• Approx. Dia. over Screen (in.): 0.92
• Jacket Thickness (Miles): 80
• Jacket Thickness (mm): 2.03

• Approx. O.D. (Inches): 1.17
• Approx. O.D. (mm): 29.7

• Approx. Net Weight: 985
• Ampacities (2) Conduit in Air: 255
• Ampacities (3) Underground Duct:
245
• Ampacities (4) Cable Tray:
335
• Part Number: 115-23-3364


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460