112-31-5764 350 MCM 3C Bare Copper Shield XLPE Binder Tape Aluminum Interlocked Armor PVC Loxarmor MC Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
112-31-5764 350 MCM 3C Bare Copper Shield XLPE Binder Tape Aluminum Interlocked Armor PVC Loxarmor MC Cable
Allowable Ampacity for 112-31-5764 350 MCM 3C Bare Copper Shield XLPE Binder Tape Aluminum Interlocked Armor PVC Loxarmor MC Cable:100 Amps
About:
The 112-31-5764 350 MCM 3C Bare Copper Shield XLPE Binder Tape Aluminum Interlocked Armor PVC Loxarmor MC Cable is designed for use in demanding electrical environments, featuring -conductor bare copper, XLPE insulation for high thermal and chemical stability, and aluminum interlocked armor for enhanced mechanical protection. It is ideal for industrial and commercial applications where robustness and electromagnetic interference shielding are required. This cable meets UL 1569 and NEC Article 330 standards, ensuring safety and performance in its applications.
Also Known As:
• 350 MCM Aluminum Interlocked Armor MC Cable
• Bare Copper Shielded MC Cable with XLPE Insulation
• PVC Jacketed Aluminum Armor Cable
Application:
Loxarmor power and control cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use on feeders and branch circuits in power distribution systems. Loxarmor power cables may be installed in both exposed and concealed work, wet and dry locations, direct burial in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater that 6 feet apart. When used with approved terminators, Loxarmor may be used in Class I and II (Division 2) and Class III (Division 1 and 2) hazardous locations - NEC Articles 501, 502 and 503.
Standards:
• UL Standard 1569 for Metal-Clad Cables, ensuring the cable meets safety requirements for fire and electrical hazards.
• National Electrical Code (NEC) Article 330, which outlines the specific installation and use guidelines for metal-clad cables.
• Possibly meets IEEE standards for shielding and performance characteristics, depending on the specific construction of the cable.
• RoHS compliant, ensuring that the materials used in the cable are free from restricted hazardous substances.
Construction:
• Conductors: Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
• Insulation: X-Olene per ICEA S-95-658/ NEMA WC-70 and UL 44. Listed UL Type XHHW-2. Meets MIL-DTL-1377H, section 4.8.4.1.2 cold bend at -66°C and ASTM D746 brittle point at -76°C.
• Conductor Identification: Base colors and tracers per ICEA S-73-532/NEMA WC-57.Sizes 8 AWG and larger, black with print number and color.
• Grounding Conductor: Bare, soft copper per ASTM B-3. Stranding per ICEA S-95-658/WC-57 and UL 1569 meets or exceeds requirements of NEC Table 250.122.
• Assembly: Per UL 1569 with binder tape overall.
• Loxarmor: Per ICEA S-95-658 NEMA WC-57, Section 4.5.7 and UL 1569.
• Jacket: When specified, black Okoseal (PVC) per UL 1569. Meets ASTM D746 brittle point at -40°C. UL Listed as Type MC cable
Features:
• Cable complies with UL 1569 for Type MC Metal-Clad Cable.
• Complete pre-packaged, factory-tested wiring system - color coded.
• Flame retardant - passes the vertical tray flame test requirements of IEEE 383-1974 and 1202, UL 1569 ICEA T29-520(210,000 BTU/hr.)
• Loxarmor cables are quality control inspected to meet or exceed applicable UL standards.
• 90°C continuous rating in wet or dry locations , 130°C emergency overload rating, 250°C short circuit rating.
• Lower installed cost compared to wire in conduit or EMT.
• Excellent compression and impact resistance.
• Easily re-routed in the event of system changes.
• UL Listed for cable tray use.
• UL Listed for direct burial.
• UL Listed sunlight resistant.
Specifications:
• Conductor Size AWG/kcmil: 350(37X)
• Number of Conductors: 3
• Insulation Thickness (miles): 65
• Grounding Conductor(s) AWG*: 3
• Core O.D. - Inches: 1.65
• Core O.D. - mm: 41.9
• Loxarmor O.D. - Inches: 1.91
• Loxarmor O.D. - mm: 48.5
• Jacket Thickness - mils: 60
• Jacket Thickness - mm: 1.52
• Approx. O.D. - Inches: 2.04
• Approx. O.D. -mm: 51.8
• NEC Ampacity(1): 350
• Approx. Net Weight: 4224
• Part Number: 112-31-5764