112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FM
nassaunationalcable.com/products/112-07-1531-500-mcm-1c-37strand-bare-copper-unshielded-epdm-okonite-fmr-xhhw-2-rw90-power-and-control-cable

Items in Cart ()

View cart

112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable

112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable
Roll over image to Zoom

112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable

SKU: 112-07-1531

Select a Gauge

112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable

Allowable Ampacity for 112-07-1531 500 MCM 1C 37Strand Bare Copper Unshielded EPDM Okonite FMR XHHW-2 RW90 Power And Control Cable:100 Amps

About:

This version of the Okonite FMR cable uses a 500 MCM size conductor made from 37-strand bare copper, providing flexibility and good conductivity. The EPDM (Ethylene Propylene Diene Monomer) insulation is known for its excellent heat, chemical, and moisture resistance, making it suitable for high-demand environments. The "XHHW-2" rating indicates that the insulation is designed for wet or dry locations at temperatures up to 90°C with an additional level of heat resistance compared to XHHW. The "RW90" designation means it can operate at 600 volts in wet or dry conditions at temperatures up to 90°C.

Also Known As:

Okonite 500 MCM XHHW-2 Cable
EPDM Insulated Copper Control Cable
Single Conductor Control Cable

Application:

Okonite-FMR Type XHH or XHHW-2 600/1000V Power and Control Cables are recommended for general low voltage power and control applications. Okonite-FMR flame retardant insulated power cables may be used in generating plants, substations and industrial plants. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, cable tray (size 1/0 AWG and larger per NEC article 392.10(B)(1)) or lashed to a messenger for aerial installation.

Standards:

• XHHW-2: This indicates compliance with standards for cross-linked high heat-resistant water-resistant insulated wire.
• RW90: 
Ensures the cable is rated for 600 volts in wet or dry conditions up to 90°C.
• NEC (National Electrical Code): 
The cable adheres to the safety standards outlined in the NEC for installation and use in accordance with various environmental and operational conditions.
• UL (Underwriters Laboratories) listed: 
This ensures that the cable has been tested for safety and performance by UL, a globally recognized safety certification organization.

Construction:

• Conductor: Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
• Insulation: 
Meets or exceeds all requirements of ICEA S-95-658, NEMA WC-70, UL 44 and CSA C22.2 No.38.  Listed by Underwriters Laboratories, Inc. as Type XHH or XHHW-2, VW-1. 0

Features:

 Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in cable tray.
 Passes the ICEA T-29-520 210,000 Btu/hr. vertical tray flame test (sizes 6 AWG and larger).
 Passes the IEEE 383-74 Vertical Tray Flame Test.
 Passes the IEEE 1202/FT4 Vertical Tray Flame Test. (sizes 1/0 AWG and larger).
 Extreme heat resistance 90°C continuous rating; 130°C emergency overload rating; 250°C short circuit rating.
 Rated 90°C wet or dry.
 Exceptional resistance to deformation at high temperatures.
 Stable electrical properties.
 Low SIC and power factor.
 Low moisture absorption.
 Mechanically rugged.
 Resistant to weather.
 Smaller diameter.
 More flexible, easier to install, terminate, or splice than XLPE insulation.
 UL Listed, UL Rated VW-1, For CT Use 1/0 AWG & larger, Oil Res I, -40C.
 cUL listed RW75 or RW90.
 UL Type RHH/RHW-2 600/1000V or 2000V, cUL Type RW75/RW90 600V or 2000V, and cUL RWU90 1000V constructions are also available.

Specifications:

• Conductor Size AWG/kcmil: 500
• Number of Strands: 37

 Insulation Thickness (mils):
65
• Insulation Thickness (mm):  1.65
• Approx. O.D (Inches): 0.87
• Approx. O.D (mm): 22.1
• 90°C Wet (1)** NEC  and CEC Ampacity: 430
• 75°C Wet (1)* NEC and CEC  Ampacity: 380
• ICEA Ampacity (2): 477
• Approx. Net Weight (Lbs): 1626
• Part Number: 112-07-1531


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com