10 AWG 12C Copper FR-XLPE LCT Shielded CPE Jacket Control Cable 600V

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
10 AWG 12C Copper FR-XLPE LCT Shielded CPE Jacket Control Cable 600V
Applications:
The 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated construction can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Also Known As:
10 AWG 12C 600V control cable XLPE shielded, FR-XLPE copper control cable 600V, Multi conductor shielded control cable, 10 AWG 12C CPE jacket control cable 600V, LCT shielded XLPE cable 600V, 10awg copper control cable shielded, 10 AWG 12C XLPE insulated control cable 600V, Flame retardant XLPE control wire, 600V shielded control cable specs, 10 AWG 12C FR XLPE CPE jacket industrial cable.
Standards:
• ASTM B3 Standard Specification for Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• UL 44 Thermoset-Insulated Wires and Cables
• UL 1277 Electrical Power and Control Tray Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
• VW-1 (Vertical-Wire) Flame Test
Construction:
Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8
Insulation:
Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
Filler:
Polypropylene filler on cables with 5 or less conductors
Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductors
LCT Shielding:
5 mils tape shield
Rip Chord:
Rip chord for ease of jacket removal
Overall Jacket:
Chlorinated Polyethylene Chloride (CPE)
Specifications:
• Size: 10 AWG
• Number of Conductors: 12
• Diameter Over Conductor (inch): 0.111
• Insulation Thickness (Mil): 30
• Jacket Thickness (Mil): 80
• Approx. OD (In): 0.984
• Copper Weight (Lbs/1000'Ft): 389
• Approx. Weight (Lbs/1000'Ft): 600
• Min Bending Radius (In): 3.3
• Allowable Ampacity In Air 90°C (Amp): 20