30 Amps (based on NEC guidelines for THW conductors in wet locations)
Applications:
This submersible pump cable is designed for continuous submersion in deep wells, water systems, and irrigation setups. It supplies power from the control panel to single-phase 230V submersible pumps and operates at 600 volts with a temperature rating of 60°C (140°F) in wet conditions.
Size 10/2 Usage: This well pump wire is designed for 2-wire deep well submersible pumps that do not require a control box. It is commonly used in residential, farm, and small commercial well installations for pump motors up to 1,5 HP.
Stranded soft annealed copper for flexibility and ease of installation.
Two current-carrying conductors plus a green ground wire, designed for 2-wire submersible pump systems.
Resistant to oil and grease.
Insulation:
Thermoplastic PVC insulation for protection against mechanical stress.
Jacket:
Black thermoplastic PVC jacket resistant to weather, ozone, sunlight, acid, alkali, and oil.
Specifications:
Gauge: 10
No. of Conductors: 2
Ground Size: 10
O.D. Inches: .305 x .729
New Weight lb/1000FT: 210 lbs
Ampacity: 30 Amps (600V rated)
Compatible with Manufacturer
Service Wire Co :
PFB10/2GG
Southwire :
563680
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Recently Viewed Products
Download PDF Spec Sheet
FAQ's
How do I wire a 2-wire submersible water pump?
A 2-wire pump has two power leads plus a green ground wire, and its start components are built into the motor, so there's no control box. Some people call it a 3-wire pump when they count the ground. 10/2 carries both power conductors and the ground. Turn off the breaker first. At the pump, splice the two cable conductors to the motor's two power leads and the ground to the motor's green lead, using a heat-shrink submersible splice kit. At the surface, land the two conductors on the pressure switch's motor (load) terminals and the ground on its ground screw. Feed the switch's line terminals from a double-pole breaker for a 230V pump, or from a single-pole breaker with hot and neutral for a 115V pump. Have a licensed electrician check the installation against local code.
Do I need a 3-wire or 4-wire setup for my pump?
Check your pump first, since the cable has to match it. A 2-wire pump has its start components inside the motor and no control box; with the ground it needs three wires, so some people call it a 3-wire setup. A pump with a control box at the surface is a 3-wire pump, which needs three conductors plus a ground, often called 4-wire. To tell which you have, look for a control box near the pressure switch, or check the motor nameplate. 10/2 is for the 2-wire (3 wires with ground) setup. If your pump has a control box, use 10/3 instead. 2-wire motors are made only up to about 1.5 HP, so larger pumps always use the control box setup.
What pump horsepower and well depth can 10/2 submersible pump cable handle?
Franklin Electric, a major US manufacturer of submersible well pump motors, publishes the cable sizing tables most installers use. Per those tables (230V single-phase, 60°C insulation, 5% voltage drop), 10 AWG copper reaches about 630 ft at 1 HP and 480 ft at 1.5 HP. Length is measured from the service entrance to the motor, so it includes the run to the wellhead plus the pump setting depth. For example, a 1.5 HP pump set at 290 ft with 120 ft back to the service panel totals 410 ft, inside the 480 ft limit. If your total run is longer, move up to 8/2. For a 3% voltage drop, multiply these lengths by 0.6, and treat your pump maker's chart as the final word for your motor. Not sure? Ask Garrie AI on nassaunationalcable.com or call NNC at 1-516-482-6313 with your pump's HP, voltage, and well depth.
Can 10/2 submersible pump cable be buried between the well and the house?
Only if the jacket is marked for it. Submersible pump cable is listed for use inside the well casing, so check the print on the 10/2 jacket for a direct burial marking before you trench it. If it isn't marked, run the buried section from the wellhead to the pressure switch or control box in UF-B or in conductors inside conduit, and join it to the pump cable at the wellhead with a listed splice or in a junction box.
Should I choose flat jacketed or twisted 10/2 pump cable?
NNC carries 10/2 in both styles. This flat cable has stranded conductors laid side by side under a black PVC jacket, which adds abrasion protection where the cable rubs the casing and lets it lie flat against the drop pipe. NNC's twisted unjacketed 10/2 has solid THW conductors twisted together with no outer jacket, so it's lighter and fits tighter clearances between the pump and the casing. Choose flat jacketed for extra protection in rough or crooked wells, and twisted when casing clearance is tight.