1/0 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA
nassaunationalcable.com/products/1-0-awg-3c-type-mv-105-copper-5-8kv-nlepr-insulation-133-100-il-aia-yellow-cpe-tp-jacket
Items in Cart ()
View cart

1/0 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow CPE-TP Jacket

1/0 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow CPE-TP Jacket
Roll over image to Zoom
1/0 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow CPE-TP Jacket
SKU: NNC258476
brands
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

1/0 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow CPE-TP Jacket

Application:

The 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket. Silicone Free

Also known as:

1/0 AWG 3C MV-105 Three Conductor Power Cable Medium Voltage 5/8kV Copper Cable Three Conductor 5/8kV Copper Power Cable 1/0 AWG 3C MV Copper Cable with NLEPR Insulation Medium Voltage Cable with CPE-TP Jacket 133% Insulation Level Copper Power Cable AIA Insulated 5/8kV 1/0 AWG 3C MV Cable Yellow CPE-TP Jacketed MV Copper Cable 105°C Rated 5/8kV Copper Cable Triple-Conductor 5/8kV Power Cable

Construction:

Conductor:
Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33optional)

Conductor Shield:
Semi-conducting cross-linked copolymer

Insulation:
115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, 

Insulation Shield: 
Strippable semi-conducting cross-linked copolymer

Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap

Grounding Conductor:
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)

Filler:
Wax paper filler

Binder:
 Polypropylene tape

Armor:
Aluminum Interlocked Armor (AIA)

Overall Jacket:
Thermoplastic Chlorinated Polyethylene (CPE-TP) 

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
• UL 1072 Medium-Voltage Power Cables
• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test

Specification:

• Size:  1/0 AWG
Number of Conductor: 3 + 1G
Number of Strands:   19
Diameter Over Conductor (inch):   0.361
Diameter Over Insulation (inch):    0.629 
Diameter Over Insulation Shield: 0.689
Ground No. x AWG: 1x4
Diameter Over Armor (inch):  1.853
Jacket Thickness (mil):  60
Approx. OD (In):  1.973
Copper Weight lb/1000ft: 1156
Approx. Weight (Lbs/1000'Ft):   2300
DC Resistance @ 25°C Ω /1000ft:   0.102
AC Resistance @ 90°Ω /1000ft:   0.128
Allowable Ampacity In Duct 90/105°C Amp :  175/190
Allowable Ampacity In Air 90/105°C Amp:  185/205


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

[short]

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460