Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25K

Items in Cart ()

View cart

Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable

Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable
Roll over image to Zoom

Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable

SKU:

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

  Product Name Length Price (Per FT.) Action
161-23-4072 1/0 AWG 1C 19Strand Aluminum Shield Full Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

161-23-4072 1/0 AWG 1C 19Strand Aluminum Shield Full Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

160-23-4081 4/0 AWG 1C 19Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

160-23-4081 4/0 AWG 1C 19Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

160-23-4093 500 MCM 1C 37Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

160-23-4093 500 MCM 1C 37Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

160-23-4096 750 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

160-23-4099 1000 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

160-23-4099 1000 MCM 1C 61Strand Aluminum Shield 1/3 Neutral EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

160-23-5090 350 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 25KV URD Cable
Product Name

160-23-5090 350 MCM 1C 37Strand Aluminum Shield 1/3 Neutral 133% EPR Concentric BC PE Okoguard URO-J 25KV URD Cable

Length
/Qty
Price (Per FT.)
Call 516-482-6313 for pricingOut Of Stock
Min: 1 FT
Max: 1000000 FT
Action

Product Information

Specification

About:

The Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable is a high-performance underground distribution cable designed for primary distribution systems. It combines the benefits of a stranded aluminum conductor with an ethylene propylene rubber (EPR) insulation, providing excellent electrical properties, flexibility, and moisture resistance. The cable is suitable for direct burial or duct installations and is engineered to meet stringent safety and reliability standards.

Also Known As:

Okoguard URD Cable
25KV URD Okoguard Cable
Okoguard EPR URD Cable

Application:

• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits.

Standards:

ICEA S-94-649: Standard for concentric neutral cables rated 5 through 46 kV
AEIC CS8: Specification for extruded dielectric shielded power cables rated 5 through 46 kV
UL 1072: Standard for medium-voltage power cables
IEEE 1202/FT4: Standard for flame propagation testing of wire & cable
NESC: National Electrical Safety Code

Construction:

• Central Conductor: Aluminum per ASTM B609, Class B stranded per B-231.
Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: Bare copper wires.
• Jacket: Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

Triple tandem extruded, all EPR system.
Okoguard cables meet or exceed ICEA standards.
Meets RUS 1728.204 for cables with filled strand or solid conductor and 100% insulation level.
105°C continuous operating temperature.
140°C emergency rating.
250°C short circuit rating.
Excellent corona resistance.
Low dielectric constant and power factor.
Screens are clean stripping.
Exceptional resistance to "treeing".
Moisture resistant.
Overall jacket provides extended life.
Red extruded stripes.
Excellent resistance to most chemicals.
Can be listed by UL as Type MV-90 on Special Orders.
CSAC68.5 listed, LTGG (-40°C), SR.
Design Options:
Additional conductor sizes
Filled strand
• Copper central conductor
Copper flat strap concentric neutral
Product identification via colored jackets
Semiconducting jackets
Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
Minimum installation temperature of -40°C.


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460