2-2-4-6 Aluminum Mobile Home Feeder Cable

2-2-4-6 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
2-2-4-6 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
2-2-4-6 Aluminum Mobile Home Feeder Cable
Roll over image to Zoom
2-2-4-6 Aluminum Mobile Home Feeder Cable
SKU: NNC1672X
over-stock-abv-3m

Select a Gauge

2-2-4-6 Aluminum Mobile Home Feeder Cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$1.85 /FT
Sale price
$1.85 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 58 reviews
97%
(56)
3%
(2)
0%
(0)
0%
(0)
0%
(0)
V
Vaughn Monagon
250’ 2-2-4-6 Aluminum Mobile Home Feeder Cable

Great price and quick shipping, all as promised.

K
Kenneth Siegford
As I would expect.

In great condition well coiled and shipped faster then advertised.

M
Michael McDonough
2-2-4-6 Aluminum Mobile Home Feeder Cable

I was very happy with the price and service of National cable. The wire sent was just as advertised and came in about 5 days.

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification


2-2-4-6 Aluminum Mobile Home Feeder Direct Burial Cable 600V

Allowable Ampacity for 2-2-4-6 Aluminum Mobile Home Feeder Cable: 100 Amps 

Applications:

2-2-4-6 Aluminum Mobile Home Feeder Cable is a 100-amp, 600V-rated service entrance cable designed to carry power from a utility meter base to the main panel in a mobile or manufactured home. It’s also used as a feeder to subpanels in modular buildings, small homes, sheds, garages, and other outbuildings.

Approved for direct burial when marked USE-2, this cable can also be installed in conduit, ducts, or raceways in wet or dry locations. Its cross-linked polyethylene insulation makes it durable and resistant to moisture, abrasion, and chemicals—ideal for underground and outdoor use.

In size 2-2-4-6, the cable is commonly used to deliver 100 amps of power to secondary panels where full-capacity circuits are needed for lighting, outlets, appliances, or HVAC systems.

Also Known As:

2-2-4-6 aluminum cable, 2-2-4-6 aluminum wire, 2-2-4-6 mobile home feeder cable, 2-2-4-6 underground feeder cable, 2-2-4-6 service entrance cable, 2-2-4-6 electrical feeder cable, 2-2-4-6 power feeder cable, 2-2-4-6 MHF cable, 2-2-4-6 direct burial wire, mobile home electrical wire, 100 amp mobile home feeder wire.

Standards:

  • Ampacities based on National Electric Code, 2005n edition, section 310-15 

  • National Electric Code (NEC)

  • UL 44 for types RHH & RHW-2 

  • UL 854 for type USE-2

  • ASTM standards B 800, B 801 

  • Sunlight resistant 

  • RUS ACCEPTED

Construction

Conductors:

The 2-2-4-6 cable includes two 2 AWG phase conductors, one 4 AWG neutral, and one 6 AWG ground. All are compact stranded 8000 series aluminum per ASTM B-800/B-801.

Insulation:

It has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.

Specifications:

  • Cable Construction: 2-2-4-6

  • Phase Conductor; Insulation (mils): 60

  • Insul. Phase Conductor; Diameter (inches): 0.390

  • Insul. Grounded (Neutral) Conductor; Diameter Inches: 0.335

  • Insul. Equipment Grounding Conductor; Diameter Inches: 0.290

  • Cable Diameter Inches: 0.944

  • New Weight lb/1000FT: 295 lbs

  • Ampacity: 100 Amps

    Compatible with Manufacturer

    Priority Wire & Cable : 2-04ALUM-MHF-R
    Houston Wire & Cable : HW023A02246
    Southwire : 30163001
    Omni Cable : MHF2-2-4-6

    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    In the case the material only comes in a predetermined color or doesn’t come with any color
    Download PDF Spec Sheet

    FAQ's

    What does 2-2-4-6 AL MHF mean?

    Two #2 AWG aluminum hot conductors, one #4 AWG aluminum insulated neutral, and one #6 AWG aluminum insulated equipment grounding conductor. All four conductors are individually insulated, rated 600V.

    What is Mobile Home Feeder (MHF) cable?

    A 4-conductor aluminum cable for feeding power from a service panel to a mobile or manufactured home. Standard configuration uses USE-2 or XHHW-2 insulation, both listed for direct burial and wet locations. The "four conductor, all insulated" construction sets it apart from standard SER, which usually has a bare ground.

    What amp rating does 2-2-4-6 aluminum MHF support?

    The #2 AWG aluminum hots are rated 90A at 75°C per NEC 310.16. However, the reduced-size #4 neutral limits 2-2-4-6 to circuits with balanced loads where the neutral does not carry the full unbalanced current. Use 2-2-2-4 AL MHF instead when the neutral needs to carry the full load. Verify terminations are rated for aluminum conductors.

    What is the difference between 2-2-2-4 and 2-2-4-6 MHF cable?

    The sequence is: hot, hot, neutral, ground. 2-2-2-4 is two #2 hots, a #2 neutral, a #4 ground. 2-2-4-6 is two #2 hots, a #4 neutral, a #6 ground. The 2-2-4-6 costs less because the neutral and ground are smaller, but the smaller neutral limits it to circuits with balanced loads. 2-2-2-4 is the safer default for a full-load service or feeder.

    Is 2-2-4-6 MHF cable rated for direct burial?

    Yes. The individual conductors inside standard MHF are USE-2 or XHHW-2, both listed for direct burial in wet locations. Follow NEC 300.5 for burial depth: 24 inches for direct-buried residential feeders under 600V, 18 inches under a concrete slab, and shallower depths where protected by conduit.

    What insulation and listing does MHF carry?

    The conductors are typically USE-2 or XHHW-2, both listed to UL 854 for service entrance and UL 44 for the conductor insulation. USE-2 stands for Underground Service Entrance, and the -2 suffix means 90°C rated in wet locations. XHHW-2 is cross-linked polyethylene with the same 90°C wet rating. The outer jacket, when present, is PVC. Voltage rating is 600V.

    Can I use MHF cable for something other than a mobile home?

    Yes, and most customers do. MHF is commonly used for pole barn feeders, detached garage subpanels, hot tub circuits, small outbuildings, and RV pedestals. It works well outside its original purpose because all four conductors are insulated, the assembly is direct-burial rated, and aluminum keeps cost reasonable at feeder sizes. Whatever the destination, code still applies: NEC 250.32 requires a 4-wire feeder to a separate structure, and MHF is already 4-wire.

    Can I splice MHF cable in the middle of a run?

    Yes, but the splice needs to be made inside a weatherproof, listed junction box using connectors rated for the conductor size and material. NEC 300.13 and 300.15 cover splice and box requirements. Direct-buried splices are allowed only if the connectors and covering are listed for direct burial. Most installations avoid buried splices by running a single continuous length.

    How far can I run 2-2-4-6 MHF for a 90A balanced-load feeder?

    Voltage drop, not ampacity, is the sizing limit at long distances. Rule of thumb for a 90A balanced load on 2-2-4-6 aluminum at 240V single phase, keeping voltage drop under 3%: about 115 to 140 ft. Beyond that, upsize the cable. Do the actual voltage-drop calculation for the specific load and run length before ordering.

    What voltage drop should I expect on 2-2-4-6 aluminum MHF?

    At 90A balanced load, 240V single phase, on 2-2-4-6 aluminum, expected voltage drop is roughly 3% at 140 ft, 5% at 225 ft, and 7% at 315 ft. Standard practice keeps total voltage drop (feeder plus branch circuits) under 5%, with the feeder itself under 3%. Use a proper calculation with the actual load current before ordering.

    Reviews

    Customer Reviews

    Based on 58 reviews
    97%
    (56)
    3%
    (2)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    V
    Vaughn Monagon
    250’ 2-2-4-6 Aluminum Mobile Home Feeder Cable

    Great price and quick shipping, all as promised.

    K
    Kenneth Siegford
    As I would expect.

    In great condition well coiled and shipped faster then advertised.

    M
    Michael McDonough
    2-2-4-6 Aluminum Mobile Home Feeder Cable

    I was very happy with the price and service of National cable. The wire sent was just as advertised and came in about 5 days.

    Get in Touch
    Live Chat Get replies right away!
    Email info@nassaunationalcable.com

    Call Us: 1-516-482-6313    Text Us: 1-516-703-3460